The prognosis of children with palate cleft treated with early tympanostomy is favorable and does not differ from children without palate cleft. Active treatment ensures normal hearing during the critical years of language, speech, and cognitive development and maintains the development of an aerated mastoid. We believe that early tympanostomy is the treatment of choice of OME in palate cleft children.
Purpose To evaluate the insertion results and hearing preservation of a novel slim modiolar electrode (SME) in patients with residual hearing. Methods We retrospectively collected the data from the medical files of 17 patients (18 ears) implanted with a SME. All patients had functional low frequency hearing (PTA (0.125-0.5 kHz) ≤ 80 dB HL). The insertion results were reexamined from the postoperative cone-beam computed tomography scans. Postoperative thresholds were obtained at the time of switch-on of the sound processors (mean 43 days) and at latest follow-up (mean 582 days). The speech recognition in noise was measured with the Finnish matrix sentence test preoperatively and at follow-up. Results The mean insertion depth angle (IDA) was 395°. Neither scala dislocations nor tip fold over were detected. There were no total hearing losses. Functional low-frequency hearing was preserved in 15/18 (83%) ears at switch-on and in 14/17 (82%) ears at follow-up. According to HEARRING classification, 55% (10/18) had complete HP at switch-on and 41% (7/17) still at follow-up. Thirteen patients (14 ears) were initially fitted with electric-acoustic stimulation and seven patients (8 ears) continued to use it after follow-up. Conclusions The preliminary hearing preservation results with the SME were more favorable than reported for other perimodiolar electrodes. The results show that the array may also be feasible for electro-acoustic stimulation; it is beneficial in that it provides adequate cochlear coverage for pure electrical stimulation in the event of postoperative or progressive hearing loss.
After training, the mean speech recognition threshold (SRT) and the slope of the final test lists were -10.1 ± 0.1 dB signal-to-noise-ratio (SNR)and 16.7 ± 1.2%/dB, respectively (measurements at constant level; inter-list variability). The mean SRT and the slope of the test subjects were -10.1 ± 0.7 dB SNR and 17.5 ± 2.2%/dB (measurements at constant level; inter-subject variability). The expected SRT range for normal-hearing young adults for adaptive measurements is -9.7 ± 0.7 dB SNR.
The genetically determined development of mastoid air cell system is arrested in varying degree by environmental factors, particularly by an early onset of otitis media, a long-standing disease, and an unfavorable otological outcome. On the other hand, poor pneumatization seems to be a risk factor for chronic and recurrent infections and, ultimately, for a deficient otological outcome. However, in a vast majority of patients, this untoward development may be reversed by an early and, if needed, repeated tympanostomy.
The overall complication rate of cochlear implant surgery is low and so-called electrode failures (electrode migration, misplacement, etc.,) account for only a minority of all complications. The aim of this study was to explore the prevalence of electrode migration as the cause for increased impedance values and non-auditory stimulation in the basal channels. Within the scope of a quality control process, the cochlear implant database of the Kuopio University Hospital (Finland) was reviewed. Patients with gradual elevation of impedance values and/or non-auditory stimulation of the basal electrode channels were re-examined and cone-beam computed tomography was administered. There were 162 cochlear implant recipients and 201 implanted devices registered in the database. A total of 18 patients (18 devices) were identified having significantly increased impedance values or non-auditory stimulation of the basal electrodes. Cone-beam computed tomography revealed extra-cochlear electrodes in 12 of these patients due to the migration of the electrode array. All extruded electrodes were lateral wall electrodes, i.e., straight electrode arrays (Cochlear CI422 and Med-El devices). The most common feature of electrode migration was the gradual increase of the impedance values in the basal electrodes, even though telemetry could also be unsuspicious. Electrode migration after cochlear implant surgery may be more common than previously reported. At surgery, special attention should be paid to the reliable fixation of the electrode array. This study underlines the importance of postoperative imaging after cochlear implant surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.