Background: Diagnostic uncertainty in CT of possible intracranial hemorrhage requires short-interval follow-up imaging, resulting in reduced efficiency of care and higher costs.Purpose: To quantify the diagnostic performance of dual-energy CT versus simulated single-energy CT in the differentiation of small foci of intracranial hemorrhage from calcium.
Materials and Methods:Images from consecutive unenhanced dual-energy CT of the head in patients from a single emergency department obtained from December 2014 to April 2016 were reviewed retrospectively for hyperattenuating intracranial foci. Ground truth was established from reference standard comparison CT or MRI. Foci were divided into development and test sets. Development set foci regions of interest were used to derive candidate CT attenuation thresholds for virtual noncalcium (VNCa) and calcium images. Test set foci were used for threshold validation, and diagnostic performance and confidence were evaluated for two readers blinded to final diagnosis. Statistical comparisons were made with exact binomial tests or repeated-measures analysis of variance.
Results:The study included 137 patients (65 years 6 17; 70 men) with 146 foci. Foci were divided into a development set (n = 105) and a test set (n = 41). Quantitative analysis of the development set produced candidate thresholds of 44 HU for VNCa images and 7 HU for calcium-only images, yielding diagnostic accuracies for the test set of 88% (36 of 41 foci; 95% confidence interval [CI]: 78%, 98%) and 95% (39 of 41 foci; 95% CI: 88%, 100%), respectively. Dual-energy CT improved reader accuracy from 90% (reader 1, 37 of 41 foci; 95% CI: 81%, 99%) and 93% (reader 2, 38 of 41 foci; 95% CI: 85%, 100%) to 100% (both readers, 41 of 41 foci; 95% CI: 100%, 100%). Diagnostic confidence (classifications rated as "certain") increased from 71% (29 of 41 foci; 95% CI: 57%, 85%) to 90% (37 of 41 foci; 95% CI: 81%, 99%) for reader 1 (P = .019) and from 46% (19 of 41 foci; 95% CI: 31%, 62%) to 85% (35 of 41 foci; 95% CI: 75%, 96%) for reader 2 (P = .0001).
Conclusion:Dual-energy CT showed high diagnostic performance in the differentiation of small foci of intracranial hemorrhage from calcium and improved diagnostic accuracy and confidence in the initial evaluation of suspected hemorrhage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.