Background Remote self-administered visual acuity (VA) tests have the potential to allow patients and non-specialists to assess vision without eye health professional input. Validation in pragmatic trials is necessary to demonstrate the accuracy and reliability of tests in relevant settings to justify deployment. Here, published pragmatic trials of these tests were synthesised to summarise the effectiveness of available options and appraise the quality of their supporting evidence. Methods A systematic review was undertaken in accordance with a preregistered protocol (CRD42022385045). The Cochrane Library, Embase, MEDLINE, and Scopus were searched. Screening was conducted according to the following criteria: (1) English language; (2) primary research article; (3) visual acuity test conducted out of eye clinic; (4) no clinical administration of remote test; (5) accuracy or reliability of remote test analysed. There were no restrictions on trial participants. Quality assessment was conducted with QUADAS-2. Results Of 1227 identified reports, 10 studies were ultimately included. One study was at high risk of bias and two studies exhibited concerning features of bias; all studies were applicable. Three trials—of DigiVis, iSight Professional, and Peek Acuity—from two studies suggested that accuracy of the remote tests is comparable to clinical assessment. All other trials exhibited inferior accuracy, including conflicting results from a pooled study of iSight Professional and Peek Acuity. Two studies evaluated test-retest agreement—one trial provided evidence that DigiVis is as reliable as clinical assessment. The three most accurate tests required access to digital devices. Reporting was inconsistent and often incomplete, particularly with regards to describing methods and conducting statistical analysis. Conclusions Remote self-administered VA tests appear promising, but further pragmatic trials are indicated to justify deployment in carefully defined contexts to facilitate patient or non-specialist led assessment. Deployment could augment teleophthalmology, non-specialist eye assessment, pre-consultation triage, and autonomous long-term monitoring of vision.
Background: Remote self-administered visual acuity (VA) tests have the potential to allow patients and non-specialists to assess vision without eye health professional input. Validation in pragmatic trials is necessary to demonstrate the accuracy and reliability of tests in relevant settings to justify deployment. Methods: A systematic review was undertaken in accordance with a preregistered protocol (CRD42022385045). The Cochrane Library, Embase, MEDLINE, and Scopus were searched. Screening was conducted according to the following criteria: (1) English languge; (2) primary research article; (3) visual acuity test conducted remotely; (4) no clinical administration of remote test; (5) accuracy or reliability of remote test analysed. There were no restrictions on trial participants. Quality assessment was conducted with QUADAS-2. Results: Of 1227 identified reports, 10 studies were ultimately included. One study was at high risk of bias and two studies exhibited concerning features of bias; all studies were applicable. Three trials—of DigiVis, iSight Professional, and Peek Acuity—from two studies suggested that accuracy of the remote tests was comparable to clinical assessment. All other trials exhibited inferior accuracy, including conflicting results from a pooled study of iSight Professional and Peek Acuity. Two studies evaluated test-retest agreement—one trial provided evidence that DigiVis is as reliable as clinical assessment. The three most accurate tests required access to digital devices. Reporting was inconsistent and often incomplete, particularly with regards to describing methods and conducting statistical analysis. Conclusions: Remote self-administered VA tests appear promising, but further pragmatic trials are indicated to justify deployment at scale to facilitate patient or non-specialist led assessment which could augment teleophthalmology, non-specialist eye assessment, pre-consultation triage, and autonomous long-term monitoring of vision.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.