Introduction:
Bone defects may be managed with bone transport or acute shortening and lengthening using circular external fixation devices. We performed a multicenter retrospective cohort study to compare the outcomes between the Ilizarov frames and hexapod frames for the management of bone defects.
Methods:
Patients treated for bone defects using either Ilizarov or hexapod frames were included for analysis in two specialist institutions. Primary outcomes were time to consolidation, bone healing index (BHI), and external fixator index (EFI). Radiographic parameters included the medial proximal tibial angle, lateral distal tibial angle, posterior proximal tibial angle, and anterior distal tibial angle.
Results:
There were 137 hexapods and 90 Ilizarov frames in total. The mean time to follow-up was 3.7 years in the hexapod group and 4.0 years in the Ilizarov group. Hexapods had a significantly lower time to consolidation (253 days versus 449 days) (P < 0.0001) and BHI (59.1 days/cm versus 87.5 days/cm) (P < 0.0001). Hexapods had a significantly better EFI (72.3 days/cm versus 96.1 days/cm) (P = 0.0009).
Conclusion:
Hexapods may confer a significant advantage over Ilizarov frames in the management of bone defects. Time to consolidation, radiographic parameters, BHI, and EFI are all superior in hexapods.
Case: A 79-year-old man 6 days status-post left total knee arthroplasty (TKA) presented to our institution from an outside hospital (OSH) after a suspected STEMI and ventricular fibrillation arrest. At the OSH, intraosseous (IO) access was placed in his right tibia. Orthopaedics was consulted for compartment syndrome at the IO access site. X-rays demonstrated this was secondary to the IO access abutting the cement mantle of a stemmed tibial component of a remote TKA, for which the patient required emergent fasciotomies.Conclusions: Healthcare providers should be cognizant of potential orthopaedic hardware that can impede proper introduction of IO access.
Establishment of intraosseous (IO) access can be a potential life-saving measure but is not without risk. In this report, we present an unusual mechanism for IO access leading to compartment syndrome with improper placement of IO access about previous orthopaedic implants.Consent for this case report was obtained from the patient's power of attorney.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.