This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Deep Inferior Epigastric Perforator Flap (DIEP) surgical procedures have benefited in recent years from the introduction of 3D printed models, yet new technologies are expanding design opportunities which promise to improve patient specific care. Numerous studies, utilizing 3D printed models for DIEP, have shown a reduction of surgical time and complications when used in addition to the review of standard CT imaging. Now, with new technology, highly detailed multi-material 3D printed models are allowing more of the information from medical imaging to be expressed in 3D printed models. This additional data, coupled with advanced digital modeling tools harnessing both voxel- and mesh-based modeling environments, is allowing for an expanded library of modeling techniques which create a wealth of concepts surgeons can use to assemble a presurgical planning model tailored to their particular setting, equipment, and needs. A DIEP free flap procedure requires locating the inferior epigastric perforator vessels traversing and perforating the rectus abdominis muscle, perfusing the abdominal skin and fatty tissue. The goal of dissecting the inferior epigastric perforator vessels is complicated by the opacity of the fatty tissue and muscle. Previous attempts to 3D print patient specific models for DIEP free flap cases from CT imaging has shown a wide range of designs which only show variations of perforator arteries, fatty tissue, and the abdominis rectus muscle. A limitation of digital surface-based modeling tools has led to existing models lacking the ability to composite critical anatomical features, such as differentiation of vessels through different tissues, coherently into one model, providing information more akin to the surgical challenge. To remedy this limitation, we have leveraged a voxel-based modeling environment to composite complex modeling elements and incorporate a ruled grid upon the muscle providing effortless ‘booleaning’ and measured guidance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.