Three-phase induction motors (IMs) are the main workhorse in industry due to their many advantages as compared to other types of industrial motors. However, the efficiency and lifetime of IMs can be considerably affected by some operating conditions, in particular those related to unbalanced supply voltages (USV), which is quite a common condition in industrial plants. Therefore, early detection and a precise severity estimation of the USV for all working conditions can prevent major breakdowns and increase reliability and safety of industrial facilities. This paper proposes a reliable method allowing for a precise and online detection of the USV condition, by monitoring a pertinent indicator calculated using the voltage symmetrical components. The effectiveness of the proposed method is validated experimentally for several different working conditions, and a comparison with other indicators available in the literature is also performed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.