This study aims to evaluate the radiation dose for transcatheter patent ductus arteriosus (PDA) via the arterial route and compare it with previously published benchmarks. BackgroundExposure to radiation in the catheterization lab can cause skin injury and cancer in the long run, especially in pediatric patients with complex heart conditions, which necessitate serial catheterizations. Therefore, measuring the patient radiation dose and establishing a benchmark for each cardiac interventional procedure is essential. Material and methodsIn this prospective study, 34 patients with transcatheter patent ductus arteriosus closure via an arterial route were included. Patients who had silent PDAs, no left heart dilatation and PDA size of less than 2mm had PDA closed via an arterial route. All the study group patients received an Amplatzer duct occluder II-additional size device (St. Jude Medical Corp, St. Paul, MN) using biplane flat-panel fluoroscopy equipment adjusted in accordance with the pediatric parameters. Patients' dose area product, air kerma and fluoroscopy time were recorded in the catheterization lab and finally compared with internationally published reference data. ResultsOf 73 patients who had transcatheter patent ductus arteriosus closure between April 2021 to December 2021, 34 patients who had a PDA closure via an arterial route were enrolled. The median age and weight were 11.5 (4-168) months and 10.5 (6-31) kg. Twenty-one (61.8%) were males, and 13 (38.2%) were males. The median radiation dose parameters were as follows: air kerma 11 (3-42) milliGray, dose area product 131 (33-443) microGray per m 2 , median dose area product indexed to weight 12 (1-48) microGray m 2 per kg, fluoroscopy time 2 (2-4) min and frame rate 15 (7.5-15) frames per second. Due to many factors, our radiation dose parameters were less than internationally published reference values for transcatheter PDA closure. ConclusionPatient selection, detailed pre-catheterization echocardiography and procedure planning are essential for accomplishing device closure of PDA with a significant reduction in radiation dose. Hemodynamic assessment in the catheterization lab is unnecessary for most PDA patients. Additionally, a next-generation imaging platform equipped with flat-panel detectors and adjusted for pediatric settings and a fluoro recording option can be used to reduce radiation exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.