Background: Cardiac air bullet injuries are rare but can be associated with significant morbidity and mortality. Case presentation: We are presenting a young male child who sustained an accidental injury to the chest by an air rifle. Bullet entered the right ventricle from the anterior part of the chest and was identified in the RV side of the interventricular septum by echocardiography and chest CT scan. There was mild pericardial effusion but no valvular injury. The bullet was removed in the cath lab, and the patient was discharged home on the second day. Conclusions: It is reasonable to try foreign body removal in the cath lab, for certain cases, and avoid cardiac surgery.
Transcatheter closure is the treatment of choice for most patent ductus arteriosus (PDA) in infants, children, and adults. However, there is a controversy regarding transcatheter closure of clinically silent PDAs. Some authors favor device closure to eliminate the lifelong risk of infective endarteritis while others recommend avoiding PDA closure in such patients. The study describes our experience of closing the silent PDAs using the Amplatzer duct occluder II-additional size (ADO II-AS) (St. Jude Medical Corp, St. Paul, MN). Materials and methodsFrom April 2018 through March 2021, 52 consecutive pediatric patients aged 18 years and less with clinically silent PDA who had transcatheter closure at our center were enrolled. Patients were excluded if they had clinically detected PDAs; had surgical ligation of PDA with no residual shunt; had left heart dilatation on echocardiography; or moderate-sized PDAs closed with ADO II-AS. In addition, patients with an innocent murmur or murmur due to an associated lesion were included. This study was retrospective, and all of the 52 patients underwent PDA device closure using ADO II-AS. ResultsFifty-two consecutive patients were enrolled with a median age of 17 months, range (97-2.5) 94.5 months. Mean weight was 11.29 kilogram, range (24.8-3.5) 21.3 kilogram, and mean follow-up was 13.5 months, range (29-0) 29 months. Thirty-one (59.6%) were females, and 21 (40.4%) were males. The mean procedure time was 30.6 min, range (60-10) 50 min, and mean fluoroscopic time was 5.5 min, range (28-1.7) 26.3 min. The mean volume of contrast given was 9.1 milliliter, range (30-4) 26 milliliter. Forty-five (45; 88.2%) patients had immediate closure of PDA. No patients had anesthetic or vascular complications; however, two patients had procedural complications. Device placement was unsuccessful in one patient with Downs syndrome. The mean follow-up for our patients was 13.5 months, range (29-0) 29 months; the patients were asymptomatic at the follow-up, and none of the patients had any residual leak. None of the patients showed coarctation or left pulmonary artery stenosis at the latest follow-up. ConclusionThe usefulness of catheter-based therapy for silent PDA is less well-established by current evidence. Further studies are needed to justify the intervention solely based on the premise that the silent duct is a substrate for infective endarteritis; however, our reason to close silent PDA was to do so primarily because of social reasons. This study found that device closure of silent PDA is safe and effective using an ADO II-AS device with minimal risk of embolization and a low residual shunt rate. Coils have been used to close small PDAs, however, with higher rates of embolization and device malpositioning. We believe ADO-II AS offers an advantage of safety and efficacy over coils. In addition, the study highlights the advantage of using an ADO II-AS device, which can be delivered via a four French delivery system with no arterial complications.
Background: Anomalous origin of one pulmonary artery from the aorta is a rare congenital anomaly affecting the right pulmonary artery more than the left. These patients are at risk for the early development of significant pulmonary hypertension. Early surgical treatment has been proven safe with excellent results. The surgical approach and technique is challenging and should be decided ahead before the patient to surgery. Different techniques were described including direct reimplantation, conduit interposition, aortic ring flap. Aim: We present a neonate with anomalous origin of the right pulmonary artery from the aorta and discuss the surgical technique and complications in the literature.
Cover Caption: The cover image is based on the Review Article Anomalous Right Pulmonary Artery from Aorta, Surgical Approach Case Report and Literature Review by Khaled Alhawri et al., https://doi.org/10.1111/jocs.15618.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.