Diaphragm electromyography is a valuable technique for the recording of electrical activity of the diaphragm. The analysis of diaphragm electromyographic (EMGdi) signal amplitude is an alternative approach for the quantification of the neural respiratory drive (NRD). The EMGdi signal is, however, corrupted by electrocardiographic (ECG) activity, and this presence of cardiac activity can make the EMGdi interpretation more difficult. Traditionally, the EMGdi amplitude has been estimated using the average rectified value (ARV) and the root mean square (RMS). In this study, surface EMGdi signals were analyzed using the fixed sample entropy (fSampEn) algorithm, and compared to the traditional ARV and RMS methods. The fSampEn is calculated using a tolerance value fixed and independent of the standard deviation of the analysis window. Thus, this method quantifies the amplitude of the complex components of stochastic signals (such as EMGdi), and being less affected by changes in amplitude due to less complex components (such as ECG). The proposed method was tested in synthetic and recorded EMGdi signals. fSampEn was less sensitive to the effect of cardiac activity on EMGdi signals with different levels of NRD than ARV and RMS amplitude parameters. The mean and standard deviation of the Pearson's correlation values between inspiratory mouth pressure (an indirect measure of the respiratory muscle activity) and fSampEn, ARV, and RMS parameters, estimated in the recorded EMGdi signal at tidal volume (without inspiratory load), were 0.38±0.12, 0.27±0.11 , and 0.11±0.13, respectively. Whereas at 33 cmH2O (maximum inspiratory load) were 0.83±0.02, 0.76±0.07, and 0.61±0.19 , respectively. Our findings suggest that the proposed method may improve the evaluation of NRD.
The current gold standard assessment of human inspiratory muscle function involves using invasive measures of transdiaphragmatic pressure (Pdi) or crural diaphragm electromyography (oesEMGdi). Mechanomyography is a non-invasive measure of muscle vibration associated with muscle contraction. Surface electromyogram and mechanomyogram, recorded transcutaneously using sensors placed over the lower intercostal spaces (sEMGlic and sMMGlic respectively), have been proposed to provide non-invasive indices of inspiratory muscle activation, but have not been directly compared to gold standard Pdi and oesEMGdi measures during voluntary respiratory manoeuvres. To validate the non-invasive techniques, the relationships between Pdi and sMMGlic, and between oesEMGdi and sEMGlic were measured simultaneously in 12 healthy subjects during an incremental inspiratory threshold loading protocol. Myographic signals were analysed using fixed sample entropy (fSampEn), which is less influenced by cardiac artefacts than conventional root mean square. Strong correlations were observed between: mean Pdi and mean fSampEn |sMMGlic| (left, 0.76; right, 0.81), the time-integrals of the Pdi and fSampEn |sMMGlic| (left, 0.78; right, 0.83), and mean fSampEn oesEMGdi and mean fSampEn sEMGlic (left, 0.84; right, 0.83). These findings suggest that sMMGlic and sEMGlic could provide useful non-invasive alternatives to Pdi and oesEMGdi for the assessment of inspiratory muscle function in health and disease.
The analysis of amplitude parameters of the diaphragm mechanomyographic (MMGdi) signal is a non-invasive technique to assess respiratory muscle effort and to detect and quantify the severity of respiratory muscle weakness. The amplitude of the MMGdi signal is usually evaluated using the average rectified value or the root mean square of the signal. However, these estimations are greatly affected by the presence of cardiac vibration or mechanocardiographic (MCG) noise. In this study, we present a method for improving the estimation of the respiratory muscle effort from MMGdi signals that is robust to the presence of MCG. This method is based on the calculation of the sample entropy using fixed tolerance values (fSampEn), that is, with tolerance values that are not normalized by the local standard deviation of the window analyzed. The behavior of the fSampEn parameter was tested in synthesized mechanomyographic signals, with different ratios between the amplitude of the MCG and clean mechanomyographic components. As an example of application of this technique, the use of fSampEn was explored also in recorded MMGdi signals, with different inspiratory loads. The results with both synthetic and recorded signals indicate that the entropy parameter is less affected by the MCG noise, especially at low signal-to-noise ratios. Therefore, we believe that the proposed fSampEn parameter could improve estimates of respiratory muscle effort from MMGdi signals with the presence of MCG interference.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.