In order to better evaluate the structural performance of the wooden floor used in the gymnasium and realize the structural optimization design, this research considered two gymnasium’s floors in Nanjing as the research object and used the transient excitation method to test the natural frequency and damping ratio parameters of the three types of floor structures. The results showed that three kinds of floor structures all meet the requirements of building comfort; under the premise that the types and specifications of the constituent materials were the same, the order of the damping ratios of the three kinds of floor structures from large to small was: the fixed floor structure with double-layer load distribution strip, the suspended floor structure with single-layer load distribution strip, and the suspended floor structure with double-layer load distribution strip; compared with the fixed floor structure, the suspended floor structure had low damping ratio characteristics, the energy dissipation was slow during structural vibration, which means its impact absorption rate was small, and its impact buffering ability was good. The integral structure had good resilience performance; compared with the floor structure using single-layer load distribution strip. The floor structure using a double-layer load distribution strip had a low damping ratio characteristic. The absorption rate of the structure was small and the resilience performance was good. The research conclusion had certain engineering application value.
The need to satisfy high seismic performance of structures and to comply with the latest worldwide policies of environmental sustainability is leading engineers and researchers to higher interest in timber buildings. A post-tensioned timber frame specimen was tested at the structural laboratory of the University of Basilicata in Italy, in three different configurations: i) without dissipation (post-tensioning only-F configuration); ii) with dissipative angles (DF- dissipative rocking configuration) and iii) with dissipative bracing systems (BF - braced frame configuration). The shaking table tests were performed considering a set of spectra-compatible seismic inputs at different seismic intensities. This paper describes the experimental estimation of energy dissipated by multistorey post-tensioned timber prototype frame with different anti-seismic hysteretic dissipative devices used in the DF and BF testing configurations. The main experimental seismic key parameters have also been investigated in all testing configurations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.