Electromechanical reshaping (EMR) provides a means of producing shape change in the cartilage by initiating oxidation–reduction reactions in mechanically deformed specimens. This paper evaluates the effect of voltage and application time on specimen shape change using needle electrodes. Rabbit septal cartilage specimens (20 mm × 8 mm × 1 mm, n = 200) were bent 90° in a precision-machined plastic jig. Optimal electrode placement and the range of applied voltages were estimated using numerical modeling of the initial electric field within the cartilage sample. A geometric configuration of three platinum needle electrodes 2 mm apart from each other and inserted 6 mm from the bend axis on opposite ends was selected. One row of electrodes served as the anode and the other as the cathode. Constant voltage was applied at 1, 2, 4, 6, and 8 V for 1, 2, and 4 min, followed by rehydration in phosphate buffered saline. Samples were then removed from the jig and bend angle was measured. In accordance with previous studies, bend angle increased with increasing voltage and application time. Below a voltage threshold of 4 V, 4 min, no clinically significant reshaping was observed. The maximum bend angle obtained was 35.7 ± 1.7° at 8 V, 4 min.
Electromechanical reshaping (EMR) of cartilage is a novel technique that has significant potential for use in facial reconstructive surgery. EMR achieves permanent shape change by initiating electrochemical redox reactions in the vicinity of stress concentrations, thereby altering mechanical properties of tissue matrix. This study reports the use of a six electrode needle-based geometric configuration to reshape cartilage. Rectangular samples (24 x 12 x 1 mm) of rabbit nasal septal cartilages were bent at a right angle in a precision-machined reshaping jig. Two parallel arrays of three platinum needle electrodes were each inserted into cartilage along the bend at 3 mm from the bend line. One array served as an anode and the other as cathode. Constant voltage at 1, 2, 4, 6, and 8 volts was applied to the arrays for 2 minutes. The specimens were then removed from the jig and rehydrated for 15 minutes in phosphate buffered saline. Following rehydration, bend angles and thicknesses were measured. Bend angle increased with increasing voltage and application time. No statistically significant bending was observed below 6 volts for 2 minutes application time. Maximum bend angle of 33 ± 8 degrees or reshaping degree of 33% was observed at 8 volts applied for 2 minutes. Current flow was small (< 0.1 A) for each case. Sample thickness was 0.9 ± 0.2 mm. ANOVA analysis showed that cartilage thickness had no significant impact on the extent of reshaping at given voltage and application time. The six needle electrode geometric configuration conforms to the voltage-and time-dependent trends predicted by previous EMR studies. In the future, the reshaping properties of other geometric configurations will be explored.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.