The 4D MUSIC technique may represent a new paradigm in MR evaluation of cardiovascular anatomy and function in children with complex congenital heart disease.
Purpose
We propose a compressed-sensing (CS) technique based on magnitude image subtraction for high spatial and temporal resolution dynamic contrast-enhanced MR angiography (CE-MRA).
Methods
Our technique integrates the magnitude difference image into the CS reconstruction to promote subtraction sparsity. Fully sampled Cartesian 3D CE-MRA datasets from 6 volunteers were retrospectively under-sampled and three reconstruction strategies were evaluated: k-space subtraction CS, independent CS, and magnitude subtraction CS. The techniques were compared in image quality (vessel delineation, image artifacts, and noise) and image reconstruction error. Our CS technique was further tested on 7 volunteers using a prospectively under-sampled CE-MRA sequence.
Results
Compared with k-space subtraction and independent CS, our magnitude subtraction CS provides significantly better vessel delineation and less noise at 4X acceleration, and significantly less reconstruction error at 4X and 8X (p<0.05 for all). On a 1–4 point image quality scale in vessel delineation, our technique scored 3.8±0.4 at 4X, 2.8±0.4 at 8X and 2.3±0.6 at 12X acceleration. Using our CS sequence at 12X acceleration, we were able to acquire dynamic CE-MRA with higher spatial and temporal resolution than current clinical TWIST protocol while maintaining comparable image quality (2.8±0.5 vs. 3.0±0.4, p=NS).
Conclusion
Our technique is promising for dynamic CE-MRA.
The rate of aneurysm rupture and death in our untreated RAA patients is zero, the growth rate is 0.60 ± 0.16 mm/y, and there were no adverse outcomes in asymptomatic RAAs >2 cm that were observed. We may currently be too aggressive in treating asymptomatic RAAs.
Keywords:Renal function Multi-parametric quantitative MRI (qMRI) Arterial spin labeling (ASL) Blood oxygen level dependent (BOLD) T1rho MRI Lupus nephritis (LN) Purpose: To identify potential biomarkers of the renal impairment in lupus nephritis using a multi-parametric renal quantitative MRI (qMRI) protocol including diffusion weighted imaging (DWI), blood oxygen level dependent (BOLD), arterial spin labeling (ASL) and T1rho MRI between a cohort of healthy volunteers and lupus nephritis (LN) patients. Materials and methods: The renal qMRI protocol was performed twice with repositioning in between on 10 LN patients and 10 matched controls at 1.5 T. Navigator-gated and breath-hold acquisitions followed by non-rigid image registration were used to control respiratory motion. The repeatability of the 4 MRI modalities was evaluated with the intra-class correlation coefficient (ICC) and within-subject coefficient of variation (wsCV). Unpaired t-test and stepwise logistic regression were carried out to evaluate qMRI parameters between the LN and control groups. Results: The reproducibility of the 4 qMRI modalities ranged from moderate to good (ICC = 0.4-0.91, wsCV ≤ 12%) with a few exceptions. T1rho MRI and ASL renal blood flow (RBF) demonstrated significant differences between the LN and control groups. Stepwise logistic regression yielded only one significant parameter (medullar T1rho) in differentiating LN from control groups with 95% accuracy. Conclusion: A reasonable degree of test-retest repeatability and accuracy of a multi-parametric renal qMRI protocol has been demonstrated in healthy volunteers and LN subjects. T1rho and ASL RBF are promising imaging biomarkers of LN.
Purpose
To study the effects of cardiac devices on three-dimensional (3D) late gadolinium enhancement (LGE) MRI and to develop a 3D LGE protocol for implantable cardioverter defibrillator (ICD) patients with reduced image artifacts.
Theory and Methods
The 3D LGE sequence was modified by implementing a wideband inversion pulse, which reduces hyperintensity artifacts, and by increasing bandwidth of the excitation pulse. The modified wideband 3D LGE sequence was tested in phantoms and evaluated in six volunteers and five patients with ICDs.
Results
Phantom and in vivo studies results demonstrated extended signal void and ripple artifacts in 3D LGE that were associated with ICDs. The reason for these artifacts was slab profile distortion and the subsequent aliasing in the slice-encoding direction. The modified wideband 3D LGE provided significantly reduced ripple artifacts than 3D LGE with wideband inversion only. Comparison of 3D and 2D LGE images demonstrated improved spatial resolution of the heart using 3D LGE.
Conclusion
Increased bandwidth of the inversion and excitation pulses can significantly reduce image artifacts associated with ICDs. Our modified wideband 3D LGE protocol can be readily used for imaging patients with ICDs given appropriate safety guidelines are followed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.