In high-resolution ion mobility spectrometry−mass spectrometry (IMS−MS)-based separations individual, pure, oligosaccharide species often produce multiple IMS peaks presumably from their α/β anomers, cation attachment site conformations, and/or other energetically favorable structures. Herein, the use of high-resolution traveling wave-based cyclic IMS−MS to systematically investigate the origin of these multiple peaks by analyzing α1,4and β1,4-linked D-glucose homopolymers as a function of their group I metal adducts is presented. Across varying degrees of polymerization, and for certain metal adducts, at least two major IMS peaks with relative areas that matched the ∼40:60 ratio for the α/β anomers of a reducing-end D-glucose as previously calculated by NMR were observed. To further validate that these were indeed the α/β anomers, rather than other substructures, the reduced versions of several maltooligosaccharides were analyzed and all produced a single IMS peak. This result enabled the discovery of a mobility fingerprint trend: the β anomer was always higher mobility than the α anomer for the cellooligosaccharides, while the α anomer was always higher mobility than the β anomer for the maltooligosaccharides. For maltohexaose, a spurious, high mobility, fourth peak was present. This was hypothesized to potentially be from a highly compacted conformation. To investigate this, α-cyclodextrin, a cyclic oligosaccharide, produced similar arrival times as the high mobility maltohexaose peak. It is anticipated that these findings will aid in the data deconvolution of IMS−MS-based glycomics workflows and enable the improved characterization of biologically relevant carbohydrates.
Herein, we report on the experimental measurements for estimated relative mobility shifts caused by changes in mass distribution from isotopic substitutions in isotopologues and isotopomers with high-resolution cyclic ion mobility separations. By utilizing unlabeled and fully labeled isotopologues with the same isotopic substitutions (i.e., 2H or 13C), we created a highly precise mobility scale for each set analyzed to determine the magnitude of such mass distribution shifts and thus calculate estimated deviations from expected, theoretical reduced mass contributions. We observed relative mobility shifts in various isotopologues (e.g., hexadecyltrimethylammonium, sucrose, and palmitic acid species) that deviated from reduced mass theory, according to the Mason–Schamp relationship, ranging in estimated magnitude from ∼0.007% up to ∼0.1% in relative mobility. More interestingly, it was found that two deuterated palmitic acid isotopomers also differed by ∼0.03% from one another in their respective relative mobility shifts. Our results are the first report of isotopologue and isotopomer separations on a commercially available cyclic ion mobility spectrometry-mass spectrometry platform. We envision that our presented mobility scale methodology will have broad applicability in studying the effect of mass distribution changes from isotopic substitutions in other biomolecules and help pave the way for the improvement of ion mobility theory and collision cross section calculators.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.