To analyze claustrophobia during magnetic resonance (MR) imaging and to explore the potential of the 26-item claustrophobia questionnaire (CLQ) (range, 0-4) as a screening tool in patients scheduled for MR imaging.
• Coronary artery disease (CAD) is a major cause of morbidity and mortality. • Invasive coronary angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest probability for CAD.
Objectives
To evaluate the influence of audio-guided self-hypnosis on claustrophobia in a high-risk cohort undergoing magnetic resonance (MR) imaging.
Methods
In this prospective observational 2-group study, 55 patients (69% female, mean age 53.6 ± 13.9) used self-hypnosis directly before imaging. Claustrophobia included premature termination, sedation, and coping actions. The claustrophobia questionnaire (CLQ) was completed before self-hypnosis and after MR imaging. Results were compared to a control cohort of 89 patients examined on the same open MR scanner using logistic regression for multivariate analysis. Furthermore, patients were asked about their preferences for future imaging.
Results
There was significantly fewer claustrophobia in the self-hypnosis group (16%; 9/55), compared with the control group (43%; 38/89; odds ratio .14; p = .001). Self-hypnosis patients also needed less sedation (2% vs 16%; 1/55 vs 14/89; odds ratio .1; p = .008) and non-sedation coping actions (13% vs 28%; 7/55 vs 25/89; odds ratio .3; p = .02). Self-hypnosis did not influence the CLQ results measured before and after MR imaging (p = .79). Self-hypnosis reduced the frequency of claustrophobia in the subgroup of patients above an established CLQ cut-off of .33 from 47% (37/78) to 18% (9/49; p = .002). In the subgroup below the CLQ cut-off of 0.33, there were no significant differences (0% vs 9%, 0/6 vs 1/11; p = 1.0). Most patients (67%; 35/52) preferred self-hypnosis for future MR examinations.
Conclusions
Self-hypnosis reduced claustrophobia in high-risk patients undergoing imaging in an open MR scanner and might reduce the need for sedation and non-sedation coping actions.
Key Points
• Forty percent of the patients at high risk for claustrophobia may also experience a claustrophobic event in an open MR scanner.
• Self-hypnosis while listening to an audio in the waiting room before the examination may reduce claustrophobic events in over 50% of patients with high risk for claustrophobia.
• Self-hypnosis may also reduce the need for sedation and other time-consuming non-sedation coping actions and is preferred by high-risk patients for future examinations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.