Background: Vascular closure devices are routinely used following femoral artery access to perform percutaneous coronary interventions (PCI). A number of devices are available on the market. We have reported previously on our experience of the Mynx device following diagnostic coronary angiography. Aims: To assess the success and complication rates of the Mynx device used in all-comers in the context of PCI within a single cardiac centre. Methods: Retrospective analysis of data available for patients who underwent PCI via the femoral route and received a Mynx device at a single tertiary centre. Results: The device was used to achieve haemostasis in 113 patients following PCI. In all cases weight-adjusted Heparin as well as dual antiplatelet therapy (Aspirin and Clopidogrel/ Ticagrelor) was administered as per PCI protocol. The device was successfully deployed in 111 cases (98.2%). The were 2 cases of device failure, one due to operator error and the other due to Mynx grip balloon bursting during device deployment. In 15 cases (13.2%; 9 male and 6 female) there were reports of small haematomas (<2cm) or oozing resulting in application of manual pressure or Femstop (St. Jude). A further patient required ultrasound-guided compression of the artery due to a large retroperitoneal bleed resulting from access complications. A larger proportion of the cases with complications were done as PPCI (44% vs 33%). The group with complications had higher systolic BP (140mmHg vs 128mmHg; P<0.05) and MABP (97mmHg vs 75mmHg; P<0.05) as compared with the group without any complications. Conclusion: The Mynx closure device is safe and easy to use in the context of PCI, in both the elective and emergency (PPCI) settings. Complication rates, predominately minor, can be minimised in experienced hands. Single-centre real world experience of the Mynx Femoral closure device in patients undergoing percutaneous coronary intervention
Background: Vascular closure devices (VCD) are routinely used to achieve haemostasis following percutaneous arterial procedures. The extravascular polyethylene-glycol based MynxGrip ® device (Cardinal Health) received FDA approval for use in the closure of femoral veins, but so far limited data is available on its use, especially with concomitant use of anticoagulants. Method: This is a retrospective analysis of data from a single-centre on the eff ectiveness and complication rates following the use of the MynxGrip ® device for femoral venous closure in patients undergoing diagnostic/interventional (temporary pacing during balloon aortic valvuloplasty, or electrophysiology) procedures utilising 5-7F sheaths. Results: 85 patients (mean age 74 years) underwent femoral venous closure with the MynxGrip ® device. 51.8% were male. The rate of concomitant anticoagulant or antiplatelet use was 52.9%. Device deployment was 100% successful with full haemostasis in all cases. There were no major vascular complications (bleeding, thrombosis, or infections). There was one case of a minor small venous hematoma which did not require treatment. The mean length of stay was less than 1 day (67.1% patients discharged the same day) and overnight stay only indicated by interventional procedure. Conclusion: This data supports safety and effi cacy of the MynxGrip ® device for femoral venous closure with same-day discharge, even with concomitant aggressive antiplatelet and anticoagulant use. It has the potential for use in other large bore venous access sites.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.