The impact on the stability of power systems is rising as the penetration level of renewable energy with sporadic natures rises rapidly on the grid. However, the impact of different types of renewable energy sources (wind, solar) and their combination on system stability varies even with the same penetration level. This paper concentrates mainly on the stability analysis of multi-machine systems connected to various types of renewable energy sources. The study presents a simple and novel control technique named automatic reactive power support (ARS) for both single and combinations of renewable sources by injecting the available reactive power into the system during fault through converters to enhance system stability. The permanent magnet synchronous generator (PMSG) and doubly fed induction generator (DFIG) are both considered as wind generators in this paper for comparison. In addition, transient stability enhancement is carried out by improving critical clearing time of a three-phase fault in the power system. With the creation of a 3-phase fault at various buses, stability analysis is carried out on the 9-bus WSCC test bus system and also on the 68-bus IEEE test system. Comparative analysis of six test case conditions is provided and the considered cases are without renewable source, with DFIG as a wind generator, PMSG as a wind generator, solar PV farm, wind farm with DFIG and solar PV in combination and the combination of wind farm with PMSG and solar PV. Moreover, the improvement in critical clearing time of the system is compared using conventional and proposed controls with all the aforementioned renewable sources. Comparative results show that the proposed control technique improves system stability and also that the combination of renewable energy sources ought to enhance the critical clearing time of system.
Most of the power electronic components act as non-linear loads because they draw non- sinusoidal current from the power supply. Due to these non-linear loads, current harmonics are injected in the power network. For normal operation, any power network is equipped with provisions to keep the harmonics level to a minimum value. Whenever a fault occurs in the distribution system, the primary goal is to re-energize the healthy part of the network which got interrupted. It can be done by changing the topology of the network. This method is called as Service Restoration (SR). In this paper, a service restoration strategy is proposed when non-linear loads are present in the radial distribution system. Service restoration problem is formulated as a multi-objective, constrained optimization problem. Three new objectives are included to address the problem of harmonics injection by non-linear loads. Multi-Objective Particle Swarm Optimization (MOPSO) and Non-Dominated Sorting Genetic Algorithm-II (NSGA-II) are used to find the optimal switching sequence for restoration. To test the effectiveness of the proposed methodology, IEEE 33 bus and IEEE 69 bus test systems are taken.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.