This assignment applies to all translations of the Work as well as to preliminary display/posting of the abstract of the accepted article in electronic form before publication. If any changes in authorship (order, deletions, or additions) occur after the manuscript is submitted, agreement by all authors for such changes must be on file with the Publisher. An author's name may be removed only at his/her written request. (Note: Material prepared by employees of the US government in the course of their official duties cannot be copyrighted.
الخالصة األهداف : ارة حر درجة غند الغسل ئل سا تخدام اس غند املتودلة ارة احلر هة مللار 5 و ية مئو 25 الزراػة هظام ات أدو تخدام ابس الزرػة موكع حتضري خالل ية مئو Elite . املواد يلة والطر : ماء خض مؼدل إن ػلام امليلنم هجاز ػىل ألبلري الفخذ غظم تخدام ابس وذكل الؼظم يف احلفر معلية خالل املتودلة ارة احلر درجة للياس اري احلر املزدوج تخدام اس مت اثبت الغسل . غند ثثبيهتا مت الغسل ماء ارة حر 5 و ية مئو 25 احلفرة ومعق ية مئو 8 اللطر و ملمي 2 ملمي . ارة حر درجة للك حفر معلية لك بؼد متت ارة احلر جسجيل معلية الليايس توى املس إىل ارة احلر لؼودة تغرق املس الوكت إىل ابإلضافة . النتاجئ : غند املربد الغسل ئل سا النتاجئ اظهرت 5 توى مس إىل احلفر غند املتودلة ارة احلر خفض ية مئو فة الغر ارة حر درجة يف ئل السا من أنرث ملحوظ . تنتاجات الاس : احلاصل الرضر يللل وابلتايل املتودلة ارة احلر يللل للزرػة الؼظمي التحضري معلية خالل مربد ماء تخدام اس للؼظم .ABSTRACT Aims: To compare heat generation when using irrigating solution at 5°C and 25°C during preparation of an implant site in bone using the tools of ELIT implant systems. Materials and Methods: Thermocouple technology was used to measure temperature level generated while drilling during osteotomy procedure for implant place in a bovine femoral cortical bone model. Drilling was accomplished by using milling machine .External irrigation at a constant ratio was used. The temperature of this irrigating solution was stabilized at 5°c and 25°C and The drilling depth was 8 mm and diameter of 2mm. Heat measurements were recorded after the final drilling for each irrigating solution in addition to time necessary to drop to base line level was recorded . Results: Results showed that cooled solution at 5 °C can decrease the temperature to a significant level better than solution at room temperature. In addition time needed to return to base line temperature levels is less than when using solution at room temperature. Conclusions: It can be concluded that the using cold irrigating solution can decrease the heat generated at implant site preparation consequently leading to decrease damage in the bone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.