This in vitro study evaluated the seal created by varying depths of mineral trioxide aggregate (MTA) plugs placed in an orthograde fashion in five groups of 10 teeth. One group received a 2 mm thick orthograde apical plug of MTA, the second group a 5 mm apical MTA plug, and the third group a 2 mm apical MTA plug with a second 2 mm increment, 24 h later. The remaining portion of the canal in these groups was left unfilled. Group four received a 2 mm MTA plug that set for 24 h and the canal was then back-filled with guttapercha and eugenol based sealer. Group five was a positive control without an MTA plug. The apical seal was tested using a bacterial leakage model of Actinomyces viscosus. Results showed a statistically significant difference in only the 5 mm apical plug, which completely prevented bacterial leakage.
BackgroundRoot canal irrigation carries a risk of extrusion of irrigant into the periapical tissues which can be associated with pain, swelling, and tissue damage. Studies have shown less extrusion with sonic or apical negative pressure devices compared with syringe and side-port needle or passive ultrasonic irrigation with continuous irrigant flow. This study aimed to evaluate the effectiveness of the EndoVac irrigation system, regarding 1) debris removal and 2) the control of apically extruded irrigating solution.MethodsFifty extracted human single-rooted teeth were used in this study. The teeth were then randomly divided into three experimental groups according to the type of irrigation used and one control group. In group 1, irrigation was performed using the EndoVac irrigation system. In group 2, irrigation was performed using a 30-gauge, tip-vented irrigation needle. In group 3, irrigation was performed using a 30-gauge, side-vented irrigation needle. The control group received instrumentation with no irrigation to serve as a control for cleaning efficiency. Root canal instrumentation was performed using the Profile NiTi rotary system with a crown-down technique. All of the experimental teeth were irrigated with the same amount of 5.25% sodium hypochlorite. The amount of extruded irrigating solution was then measured by subtracting the post-instrumentation weight from the pre-instrumentation weight using an electronic balance. The cleanliness of debris removal was evaluated using scanning electron microscopy.ResultsEndoVac irrigation had the least amount of extrusion followed by the side-vented and tip-vented method. The difference between the groups was statistically significant (P <0.01). As for the cleaning results, the debris collection in the EndoVac and tip-vented groups was the least in the apical third. In the control and the side-vented groups, the debris was the greatest in the apical third, but this difference was not significant among the three experimental groups.ConclusionsThe EndoVac irrigation system extruded significantly less irrigant solution than either needle irrigation system. Debris collection was the least in the apical third for the EndoVac irrigation system. No significant difference was found in the cleaning efficiency among the three irrigation systems.
Objective To evaluate the push-out bond strength of Biodentine (BD) in comparison with two available calcium silicate based materials, bioaggregate (BA) and ProRoot MTA (WMTA). Materials and methods One hundred and twenty-three root dentin slices of freshly extracted single rooted human teeth were randomly divided into three groups (n = 41) according to the used test material: WMTA, BA, BD. After canal space preparation, the filling materials were placed inside the lumen of the slices. After 72 hours, the maximum force applied to materials at the time of dislodgement was recorded and slices were then examined under a stereomicroscope at ×40 magnification to determine the nature of bond failure. Analysis of variance (ANOVA) test was used to compare means of push-out bond strength. Post-hoc test was then accomplished for multiple comparisons. Chi-square test was used to determine if there is significant association between the type of material and type of failure. Results The mean push-out bond strength ± standard deviation in MPa values of WMTA, BA and BD were 23.26 ± 5.49, 9.57 ± 3.45, 21.86 ± 6.9, respectively. There was no significant difference between the means of WMTA and BD (p = 0.566), but the mean of BA was significantly lower than those of WMTA and BD (p = 0.000). Under stereomicroscope, WMTA and BA showed a majority of mixed type of failure than cohesive failure, while BD showed the opposite. No adhesive failure was observed in any specimen. Conclusion The findings of the present study imply that the force needed for BD displacement is similar to WMTA and significantly higher than the force required to displace BA. How to cite this article Alsubait SA, Hashem Q, AlHargan N, AlMohimeed K, Alkahtani A. Comparative Evaluation of Push-out Bond Strength of ProRoot MTA, Bioaggregate and Biodentine. J Contemp Dent Pract 2014;15(3):336-340.
Background: Ultrasonography is a non-invasive method of diagnosing periapical lesions while radiologic methods are more common. Periapical lesions due to endodontic infection are one of the most common causes of periapical radiolucency that need to be distinguished to help determine the course of treatment. This review aimed to examine the accuracy of ultrasound and compare it to radiographs in distinguishing these lesions in vivo. Methods: This review process followed the PRISMA guidelines. A literature search of databases (PubMed, Scopus, Embase, and Web of Science) was conducted without any restrictions on time. Articles available in English were included. The selection was done according to the inclusion and exclusion criteria. The QUADAS-2 tool was used to assess the quality of the studies. Results: The search provided a total of 87 articles, out of which, five were selected for the final review. In all the studies, ultrasound had higher accuracy in distinguishing periapical lesions. All the studies indicated a risk of bias, especially in patient selection. Conclusion: Within limitations, the study indicates that ultrasound is a better diagnostic tool to distinguish periapical lesions compared to radiographs but further studies with well-designed, rigorous protocols and low risk of bias are needed to provide stronger evidence.
Stem cells from human exfoliated deciduous teeth (SHEDs) are considered a type of mesenchymal stem cells (MSCs) because of their unique origin from the neural crest. SHEDs can self-renewal and multi-lineage differentiation with the ability to differentiate into odontoblasts, osteoblast, chondrocytes, neuronal cells, hepatocytes, adipocytes, etc. They are emerging as an ideal source of MSCs because of their easy availability and extraordinary cell number. Ascorbic acid, or vitamin C, has many cell-based applications, such as bone regeneration, osteoblastic differentiation, or extracellular matrix production. It also impacts stem cell plasticity and the ability to sustain pluripotent activity. In this study, we evaluate the effects of ascorbic acid on stemness, paracrine secretion, and differentiation into osteoblast, chondrocytes, and adipocytes. SHEDs displayed enhanced multifaceted activity, which may have applications in regenerative therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.