Different techniques for monitoring the transformer condition are continuously discussed. This is due to the fact that transformers are one of the most expensive components in the power system network. Not to mention the cost to fix any failure occurred in the transformer that have becoming more expensive nowadays. Frequency response analysis (FRA) is found to be the best method to monitor the transformer reliability. This paper presents a continuation of study presented in previous paper [1]. The study performed a laboratory test to show that the response of a normal winding phase A can be affected by short circuit fault which occurred at LV winding phase a, b, and c. To further investigate, current paper performed FRA measurement and applied fault on all phases. The same procedure is repeated on a distribution transformer to verify the findings. This is to examine the effect of fault at winding of other phases to the response of measured phase.
Frequency response analysis (FRA) method has been proven to detect the transformer winding damage. However, there is no practical study which investigates the damages on transformer tap changer even though it has a high failure rate. Hence, this paper investigates normal and faulty transformer tap changer using FRA. The FRA measurements conducted using four different test configurations. Also, normal tap changer, pitting and coking tap changer contact were investigated. In addition to FRA measurement, winding resistance measurement has been conducted. The transformer turn ratio measurement also conducted to identify the taps positions. This study results significant to understand the effect of pitting and coking tap changer on the transformer frequency response. The results showed that pitting has a slight influence on the frequency response. However, coking shows a huge variation in low-frequency response. This effect observed during the winding resistance measurement.
Cooperative communication systems, which make use of the intermediate relays between the transmitter and the receiver, have been employed as an effective technique to combat the channel fading and to enhance system performance. Cooperative systems have some drawbacks such as high latency and may diversity order not guaranteed. To alleviate the negative effects of these factors, the relay selection protocol is employed in cooperative communication systems to increase overall cooperative system performance. Relay selection in the cooperative systems enables the source to cooperate with the single relay node rather than multiple relay nodes which guaranteed the diversity order.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.