One fault that occurs with heat exchangers is a tube rupture, an overpressure scenario in which high pressure fluid flows into the low pressure region. It is a serious safety concern that may lead to significant damage. Accurate prediction of the pressure build-up after a rupture is critical to determine the appropriate size of a relief device and avoid exceeding allowable pressure limits. This paper describes a model-based step-by-step methodology to predict dynamic pressure profiles during tube rupture for liquid-liquid, vapor-liquid, and flashing liquid-liquid systems. The transient effects of the relief valve are considered. The effects of choked flow must also be considered for accurate maximum pressure predictions. Using a dimensionless analysis, the pressure ratio and density ratio are shown to significantly impact the severity of this incident. Results show that vapor-liquid systems result in the highest pressure surges.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.