An experimental study was conducted to evaluate the efficiency of patch repair to rehabilitate corrosion-defected reinforced concrete (RC) beam-column members when exposed to bending moments and axial forces. Ten RC beam-column members were tested under combined constant axial force and four-point transverse load up to failure. Two levels of the constant axial force were applied at either 15 kN or 30 kN (i.e., 25% or 50% of the ultimate design load of the control specimen). The accelerated corrosion process was used to get steel reinforcement corrosion inside the concrete of three levels, 0% and approximately 5% and 20%, according to Faraday’s law. The patch repair technique of cleaning or replacing corroded steel bars and replacing the damaged concrete cover with new mortar was used in this study. The experimental results of the corrosion-defected specimens showed a significant deterioration in the structural performance and the integrity by reducing ultimate capacity, stiffness, serviceability, and ductility. Additionally, the effect of increasing axial force was recorded clearly by reducing the adverse effect of corrosion, especially for defected specimens with high corrosion level. The deterioration of corrosion reinforcement could be overcome when using a patch repair technique, which restored the undamaged state and was shown clearly by using a patch repair technique with replacing corroded steel bars.
The efficiency of external strengthening using CFRP (Carbon Fiber Reinforced Polymer) sheets to rehabilitate corrosion-defected RC (Reinforced Concrete) beam-column members is experimentally studied. ALL specimens were tested under a combined axial force and transverse load until failure. The axial forces were applied with two levels either 25% or 50% of the ultimate design load of control specimen. The accelerated corrosion process was used to get steel reinforcement corrosion inside the concrete at three levels, 0% and approximately 5% and 20%, according to Faraday's law. External strengthening with a CFRP sheet was used in this study to overcome the effect of deterioration in the mechanical properties of the corroded steel bars. A significant deterioration in the load carrying capacity, stiffness, and serviceability was recorded for corrosion-defected specimens. The increase of the axial force was recorded as a positive effect on the ultimate strength, stiffness, and serviceability of the testing specimens. This effect was clearly evident for the defected specimens, with an increasing corrosion level, by decreasing the adverse effects of corrosion. The external strengthening with a CFRP sheet restored the load-carrying capacity, stiffness, and serviceability to an undamaged state.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.