We present a new Short-Open-Load-Thru (SOLT) calibration method for on-wafer S-parameter measurements. The new calibration method is based on a 10-term error model which is a simplified version of the 16-term error model. Compared with the latter, the former ignores all signal leakages except the ones between the probes. Experimental results show that this is valid for modern vector network analyzers (VNA). The advantage of using this 10-term error model is that the exact values of all error terms can be obtained by using the same calibration standards as the conventional SOLT method. This avoids not only the singularity problem with approximate methods, such as least squares, but also the usage of additional calibration standards. In this paper, we first demonstrate how the 10-term error model is developed and then the experimental verification of the theory is given. Finally, a practical application of the error model using a 10 dB attenuator from 140 GHz to 220 GHz is presented. Compared with the conventional SOLT calibration method without crosstalk corrections, the new method shows approximately 1 dB improvement in the transmission coefficients of the attenuator at 220 GHz.
In this paper, we present a two-port on-wafer scattering parameter measurement method to tackle the issue of crosstalk between probes. The proposed method treats the crosstalk separately during the system calibration and the device measurement stages, because the crosstalk during these stages is often different due to changes in the measurement conditions after the probes have been calibrated. For example, devices under test (DUTs) and calibration standards are often situated on different substrates, or, the distance between probes during calibration is different from that during DUT measurement. Based on this concept, we develop a new error model in which the crosstalk is treated as a standalone two-port error network in parallel with the two-port calibration standards or DUTs. The two-port crosstalk error generated during probing, ECT, is removed in the system calibration and corrected during the measurement of the DUT by using a dummy pair of open-circuit standards that are fabricated on the same substrate as the DUT. Since the crosstalk is corrected while measuring the DUT, rather than during system calibration, we call this method "calibration on the fly" (COF). The method is demonstrated using measurements of a 10-dB attenuator between 140 GHz and 220 GHz.
-We present the development of a verification technique for on-wafer noise figure (NF) measurement systems. As the key element of the technique, a verification device consisting of a mismatched attenuator and a low noise amplifier (LNA) has been developed. The attenuator and the LNA are fabricated on two separate chips but joined with a bondwire. The verification procedure based on the device has also been developed and tested on an on-wafer vector network analyzer system with a noise measurement option across the frequency range from 2 GHz to 20 GHz. It has also been found that the bondwire contributes to negligible effect on the system when NF is high e.g. 3 dB but slightly higher when NF is smaller e.g. 1 dB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.