OBJECTIVE The Woven Endobridge (WEB) device has been in clinical use for the treatment of brain aneurysms for the past 4 years. Observational studies to assess clinical outcome and related complications have been published. Clear evidence is required to better understand the safety profile of the WEB device. The authors here present a multicenter series that provides a detailed safety analysis focused on patient selection, procedural events, and technical issues of treated patients throughout the United Kingdom (UK). METHODS A nationwide password-protected database was set up to collect anonymous information across the UK (14 centers). Complications and clinical outcome were analyzed for the initial 109 patients (112 procedures). An independent root cause analysis classified the complications into groups (procedural, disease, device, ancillary device, and other). The modified Rankin Scale (mRS) was used as a marker of clinical outcome. RESULTS Each of the 109 patients had 1 aneurysm suitable for WEB treatment (109 aneurysms). Three patients had 2 procedures, making a total of 112 procedures performed. Eight procedures were abandoned because of access issues; 2 patients went on to have a successful procedure. All 109 patients had a preprocedure and discharge mRS scores recorded. One hundred patients had a recorded mRS score from a > 3-month follow-up. Deployment of the WEB device was successful in 103 (94.5%) of 109 patients and 104 (92.9%) of 112 procedures. One patient had 2 successful WEB procedures on separate occasions. Patients without a successfully implanted WEB device were included in the analysis. Selection analysis showed that the average patient age was 56.5 years among 34 men and 75 women. The percentage of incidental aneurysms was 58.7%, acute 16.5%, symptomatic 18.3%, and recurrent 6.4%. Further results analysis showed that 40 (36.7%) of 109 patients had recorded adverse events, including those unrelated to the WEB device. Events that could be related to the WEB device numbered 17 (15.6%) among the 109 patients. Two patients with device-related complications were symptomatic. Overall, 11 patients (10.1%) had persistent clinical sequelae. Thromboembolism was the most prevalent event, affecting 15.6% of the patients (17 of 109), and 6.4% of the patients (7 of 109) with a thromboembolism were symptomatic. Overall mortality before discharge was 0% and at the > 3-month follow-up was 5% (5 of 100 patients). Morbidity was defined as an mRS score increase to > 2. Overall morbidity at discharge was 1.8% (2 of 109) and at the > 3-month follow-up was 6% (6 of 100). No device-related morbidity or mortality was associated with this group. CONCLUSIONS The UK data show that the WEB device is safe for clinical use. Thromboembolic complication adds a risk that should be minimized with appropriate anticoagulation and correct sizing of the device. There is scope for further evaluation and standardization of an anticoagulation regimen for the WEB device.
OBJECTIVE The Woven EndoBridge (WEB) is an innovative new technique for securing cerebral aneurysms. It is designed particularly for wide-necked bifurcation aneurysms that otherwise would be difficult to treat. There is a paucity of follow-up data in the literature due to the novelty of this technique. The authors reviewed their data from cases involving patients treated at Leeds General Infirmary with the WEB device. They assessed the safety and complication risk associated with the device and clinical and radiological follow-up outcomes in their patients. This is, to their knowledge, the first publication to include the new single-layer sphere device (WEB SLS) in addition to the original dual-layer (WEB DL) and the (nonsphere) single-layer (WEB SL) devices. METHODS Data from 22 patients who underwent 25 WEB treatments were analyzed. Of the 25 WEB procedures, 3 were performed on an acute basis, 1 was performed on a semiacute basis, and the remaining 21 were elective. A novel 6-point scoring system called the Leeds WEB aneurysm occlusion scale was created to ensure accurate assessment based on the morphology of the WEB device. Outcome was assessed at follow-up by MR angiography with or without digital subtraction angiography and the modified Rankin Scale (mRS). RESULTS Deployment of the WEB device was successful in 22 (88%) of 25 procedures; 3 (12%) of the attempts at WEB treatment were abandoned. One of the patients in whom treatment was abandoned underwent a successful second attempt. Immediately after the 22 procedures with successful deployment, 4 (18%) of the patients had a complete occlusion of the aneurysm and WEB device; 10 (45%) had varying degrees of occlusion within the WEB device but no aneurysm neck or remnant; 3 (14%) had a neck remnant; and 5 (23%) had an aneurysm remnant. Of the patients with an aneurysm remnant, 1 had a complete aneurysm occlusion at ≥ 3-months follow-up. In total, 6 (27%) patients had a residual aneurysm at ≥ 3-months radiological follow-up. One of these patients was admitted with hydrocephalus secondary to a recurrent aneurysm and later received a second WEB treatment with additional coiling. Only 1 patient developed new neurological symptoms. This patient went from an mRS score of 0 to a score of 1 and had radiological evidence of a thromboembolic event. Two patients showed radiological evidence of a new thromboembolic event on follow-up MRI but were clinically asymptomatic. CONCLUSIONS The WEB has shown itself to be a promising new device with the potential to increase the scope of treatment for difficult wide-necked bifurcation aneurysms. The technique is safe, and short-term results show effective occlusion of complex aneurysms with minimal complications associated with the procedure. Long-term efficacy, however, still needs to be assessed.
We present our initial patient experience with an innovative temporary bridging device, the Comaneci (Rapid Medical, Israel), to assist in the coiling of cerebral aneurysms. The Comaneci device confers the same benefits as balloon remodeling but without the risks of parent artery occlusion. This alleviates time pressure on the clinician, and could reduce the risk of parent artery thrombosis. Three patients were treated with the Comaneci device. Two patients had acute ruptured posterior communicating aneurysms and one patient was treated electively for a carotico-ophthalmic aneurysm. Excellent occlusion of all three aneurysms was obtained. One patient developed a distal middle cerebral artery clot, that was treated with intravenous aspirin, with minor neurological consequences. These early results show that the Comaneci device can be used to achieve good cerebral aneurysm occlusion. Vessel patency is maintained throughout the procedure with potential advantages over conventional balloon assisted coiling.
We present our initial patient experience with an innovative temporary bridging device, the Comaneci (Rapid Medical, Israel), to assist in the coiling of cerebral aneurysms. The Comaneci device confers the same benefits as balloon remodeling but without the risks of parent artery occlusion. This alleviates time pressure on the clinician, and could reduce the risk of parent artery thrombosis. Three patients were treated with the Comaneci device. Two patients had acute ruptured posterior communicating aneurysms and one patient was treated electively for a carotico-ophthalmic aneurysm. Excellent occlusion of all three aneurysms was obtained. One patient developed a distal middle cerebral artery clot, that was treated with intravenous aspirin, with minor neurological consequences. These early results show that the Comaneci device can be used to achieve good cerebral aneurysm occlusion. Vessel patency is maintained throughout the procedure with potential advantages over conventional balloon assisted coiling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.