The aim of the present study was to evaluate the potential for the production of edible oil from organically grown camelina ( Camelina sativa L. Crantz), focusing on the influence of environmental factors on nutritional quality parameters. Field experiments with precrop barley were conducted in Norway in the growing seasons 2007, 2008, and 2009. Trials were fully randomized with two levels of nitrogen (N) fertilization, 0 and 120 kg total N ha(-1), and two levels of sulfur (S) fertilization, 0 and 20 kg total S ha(-1). Weather conditions, that is, temperature and precipitation, were recorded. Additional experiments were performed in the years 2008 and 2009 to evaluate the effects of replacing precrop barley with precrop pea. Seed oil content was measured by near-infrared transmittance, and crude oil compositions of fatty acids, phytosterols, tocopherols, and phospholipids were analyzed by chromatography and mass spectrometry. Results showed significant seasonal variations in seed oil content and oil composition of fatty acids, tocopherols, phytosterols, and phospholipids that to a great extent could be explained by the variations in weather conditions. Furthermore, significant effects of N fertilization were observed. Seed oil content decreased at the highest level of N fertilization, whereas the oil concentrations of α-linolenic acid (18:3n-3), erucic acid (22:1n-9), tocopherols, and campesterol increased. Pea compared to barley as precrop also increased the 18:3n-3 content of oil. S fertilization had little impact on oil composition, but an increase in tocopherols and a decrease in brassicasterol were observed. In conclusion, organically grown camelina seems to be well suited for the production of edible oil. Variations in nutritional quality parameters were generally small, but significantly influenced by season and fertilization.
A low-cost Fourier transform infrared (FTIR) instrument was developed where the traditional He-Ne reference laser was replaced by a low-cost linear encoder. An RMS sampling error of less than 20 nm was achieved by oversampling both the interferogram and the encoder signal and then resampling the interferogram using a correction table for the encoder. A gas calibration model was developed for the system, which was chosen to have a stroke length of 21 mm and, thereby, a resolution of 0.4 cm(-1) after apodization. The instrument was mounted on a vehicle and employed in an agricultural field test for measuring soil emissions, in particular nitrous oxide (N(2)O). The concentration of N(2)O was measured with a root mean squared error of 6 ppb. The results compared well with lab-based gas chromatography measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.