Background High-dose-rate (HDR) intracavitary-interstitial brachytherapy (IC-ISBT) is an effective treatment for bulky, middle, and advanced cervical cancer. In this study, we compared the differences between 60Co and 192Ir HDR IC-ISBT plans in terms of radiobiological and dosimetric parameters, providing a reference for clinical workers in brachytherapy. Methods A total of 30 patients with cervical cancer receiving HDR IC-ISBT were included in this study, and IC-ISBT plans for each individual were designed with both 60Co and 192Ir at a prescribed dose of CTV D90 = 6 Gy while keeping the dose to OARs as low as possible. Physical dose and dose–volume parameters of CTV and OARs were extracted from TPS. The EQD2, EUBED, EUD, TCP, and NTCP were calculated using corresponding formulas. The differences between the 60Co and 192Ir IC-ISBT plans were compared using the paired t-test. Results In each patient's 60Co and 192Ir IC-ISBT plan, the average physical dose and EQD2 of 60Co were lower than those of 192Ir, and there were statistically significant differences in D2cc and D1cc for the OARs (p < 0.05); there were statistically significant differences in D0.1 cc for the bladder (p < 0.05) and no significant differences in D0.1 cc for the rectum or intestines (p > 0.05). The EUBED ratio (60Co/192Ir) at the CTV was mostly close to 1 when neither 60Co or 192Ir passed their half-lives or when both passed two half-lives, and the difference between them was not significant; at the OARs, the mean value of 60Co was lower than that of 192Ir. There was no statistical difference between 60Co and 192Ir in the EUD (93.93 versus 93.92 Gy, p > 0.05) and TCP (97.07% versus 97.08%, p > 0.05) of the tumors. The mean NTCP value of 60Co was lower than that of 192Ir. Conclusions Considering the CTV and OARs, the dosimetric parameters of 60Co and 192Ir are comparable. Compared with 192Ir, the use of 60Co for HDR IC-ISBT can ensure a similar tumor control probability while providing better protection to the OARs. In addition, 60Co has obvious economic advantages and can be promoted as a good alternative to 192Ir.
Purpose To compare inverse planning simulated annealing (IPSA) and hybrid inverse planning optimization (HIPO) using dosimetric and radiobiological models, and provide a basis for selecting the optimization method for cervical cancer. Material and methods This was a retrospective study including 32 patients with radical cervical cancer. Brachytherapy treatment plans were re-optimized using IPSA, HIPO1 (with a locked uterine tube), and HIPO2 (with an unlocked uterine tube). Dosimetric data, including isodose lines, HR-CTV (D 100 , V 150% , V 200% , HI, and CI), and (bladder, rectum, and intestines) D 1cc , D 2cc for organs at risk (OARs) were also collected. Additionally, TCP, NTCP, BED, and EUBED were calculated, and differences were analyzed using matched samples t -test and Friedman test. Results Compared with IPSA and HIPO2, HIPO1 had better V 150% and V 200% ( p < 0.05). Compared with IPSA and HIPO1, HIPO2 had better D 100 and CI ( p < 0.05). The doses to the bladder D 1cc (4.72 ±0.33 Gy)/D 2cc (4.47 ±0.29 Gy) and rectum D 1cc (4.50 ±0.61 Gy)/D 2cc (4.11 ±0.63 Gy) were lower in HIPO2 than in IPSA and HIPO1. EUBEDs for HR-CTV were higher in HIPO1 and HIPO2 than in IPSA by 1.39-1.63%. However, TCPs were not remarkably different among the three plans ( p > 0.05). Also, the NTCP for the bladder was lower in HIPO2 than in IPSA and HIPO1 by 13.04% and 16.67%, respectively. Conclusions Although the dosimetric parameters of IPSA, HIPO1, and HIPO2 are comparable, HIPO2 provides better dose conformability and lower NTCP. Therefore, HIPO2 is recommended as an optimization algorithm in IC/ISBT for cervical cancer.
High-dose-rate (HDR) brachytherapy (BT) is an essential treatment for cervical cancer, one of the most prevalent gynecological malignant tumors. In HDR BT, high radiation doses can be delivered to the tumor target with the minimum radiation doses to organs at risk. Despite the wide use of the small HDR 192Ir source, as the technique has improved, the HDR 60Co source, which has the same miniaturized geometry, has also been produced and put into clinical practice. Compared with 192Ir (74 days), 60Co has a longer half-life (5.3 years), which gives it a great economic advantage for developing nations. The aim of the study was to compare 60Co and 192Ir sources for HDR BT in terms of both dosimetry and clinical treatment. The results of reports published on the use of HDR BT for cervical cancer over the past few years as well as our own research show that this treatment is safe and it is feasible to use 60Co as an alternative source.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.