Background: Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has been proven to be lethal to human health, which affects almost every corner of the world. The objectives of this study were to add context to the global data and international genomic consortiums, and to give insight into the efficiency of the contact tracing system in Oman. Methods: We combined epidemiological data and whole-genome sequence data from 94 samples of SARS-CoV-2 in Oman to understand the origins, genetic variation, and transmissibility. The wholegenome size of sequence data was obtained through a customized SARS-COV-2 research panel. Amplifier methods ranged from 26 Kbp to 30 Kbp and were submitted to GISAID. Findings: The study found that P323L (94.7%) is the most common mutation, followed by D614G (92.6%) Spike protein mutation. A unique mutation, I280V, was first reported in Oman and was associated with a rare lineage, B.1.113 (10.6%). In addition, the study revealed a good agreement between genetic and epidemiological data. Interpretation: Oman's robust surveillance system was very efficient in guiding the outbreak investigation processes in the country, the study illustrates the future importance of molecular epidemiology in leading the national response to outbreaks and pandemics.
Background:Increasing evidence shows that good compliance with occlusion therapy is paramount for successful amblyopia therapy.Purpose:To study the degree of compliance and explore factors affecting compliance in patients undergoing occlusion therapy for amblyopia in our practice.Design:Nonrandomized clinical intervention study.Materials and Methods:A total of 31 families with a child (aged 2-12 years), undergoing unilateral amblyopia treatment at the pediatric ophthalmology clinic of Sultan Qaboos University Hospital, Oman, were recruited for this one month study. Parents were interviewed and completed a closed-ended questionnaire. Clinical data including, visual acuity, refraction, diagnosis and treatment, for each patient was collected from the hospital chart and was entered in a data collection sheet. Compliance with occlusion therapy was assessed by self-report accounts of parents and was graded into good, partial, or poor. Association between various factors and degree of compliance was studied using logistic regression modeling.Results:Only 14 (45%) patients showed good compliance to occlusion therapy. 17 (55%) patients were noncompliant. Improvement in visual acuity strongly correlated with compliance to patching (P = 0.008). Other variables that were studied included, age at onset of therapy; gender; degree of amblyopia; type of amblyopia; use of glasses; and compliance with glasses. These did not emerge as significant predictors of compliance. All but one family with poor compliance stated that the main challenge in following the recommendation to patch for requisite hours was in getting their child to cooperate. Only in one instance, the family cited nonavailability of patches as the main hindrance to compliance. 10/31 (32%) families expressed a desire for more information and 18/31 (58%) parents did not understand that amblyopia meant decreased vision.Conclusion:Poor compliance is a barrier to successful amblyopia therapy in our practice. Improvement in visual acuity is associated with better compliance with patching. Parents find it difficult to comprehend and retain verbal explanations of various components regarding occlusion therapy for amblyopia. Future study with a larger sample of patients is recommended to investigate the factors affecting compliance with amblyopia therapy and determine predictors for poor compliance.
Background:To assess the technique of glaucoma eye drop instillation in patients who have and have not attended glaucoma education sessions. To compare this with their subjective perception of eye drop use and identify factors associated with improved performance.Patients and Methods:An observational study of 55 participants who instill their topical glaucoma medication for more than 1 year. Twenty-five patients attended (A) glaucoma teaching sessions >1 year before the study and were compared to thirty patients who never attended (NA). Patients completed a self-reporting questionnaire. They instilled their eye drop, and the technique was video-recorded digitally and later graded by two masked investigators. The results were analyzed using Fisher's exact test and Chi-square test. Predictors were assessed using logistic regression models.Results:There was no significant difference in overall performance scores between the two groups. Good technique was observed in 16% of (A) group versus 23% (NA) group, (P = 0.498). There was a mismatch between patient's subjective and actual performance. Female gender and higher educational level were found to be predictors of good performance of drop instillation on univariable logistic regression analysis.Conclusion:Glaucoma patients are challenged with eye drop instillation despite receiving education on drop administration. There is a discrepancy between patient's perceptions and observed technique of drop administration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.