In the present paper, a solid phase extraction system for separation and preconcentration of nickel (ng g(-1)) in saline matrices is proposed. It is based on the adsorption of nickel(II) ions onto an Amberlite XAD-2 resin loaded with 1-(2-pyridylazo)-2-naphthol (PAN) reagent. Parameters such as the pH effect on the nickel extraction, the effect of flow rate and sample volume on the extraction, the sorption capacity of the loaded resin, the nickel desorption from the resin and the analytical characteristics of the procedure were studied. The results demonstrate that nickel(II) ions, in the concentration range 0.10-275 microg l(-1), and pH 6.0-11.5, contained in a sample volume of 25-250 ml, can be extracted by using 1 g Amberlite XAD-2 resin loaded with PAN reagent. The adsorbed nickel was eluted from the resin by using 5 ml 1 M hydrochloric acid solution. The extractor system has a sorption capacity of 1.87 mumol nickel per g of Amberlite XAD-2 resin loaded with PAN. The precision of the method, evaluated as the R.S.D. obtained after analyzing a series of seven replicates, was 3.9% for nickel in a concentration of 0.20 microg ml(-1). The proposed procedure was used for nickel determination in alkaline salts of analytical grade and table salt, using an inductively coupled plasma atomic emission spectroscopy technique (ICP-AES). The standard addition technique was used and the recoveries obtained revealed that the proposed procedure shows good accuracy.
An assisted liquid-liquid extraction of copper, iron, nickel and zinc from vegetable oil samples with subsequent determination by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) was optimized by applying a full factorial design in two levels and the response surface methodology, Box-Behnken. The effects of the acid concentration and the amplitude, cycle and time of sonication on the extraction of the analytes, as well as their interactions, were assessed. In the selected condition (sonication amplitude = 66%, sonication time = 79 s, sonication cycle = 74%), using 0.5 mol L(-1) HCl as the extractant, the limits of quantification were 0.14, 0.20, 0.21 and 0.04 μg g(-1) for Cu, Fe, Ni and Zn, respectively, with R.S.D. ranging from 1.4% to 3.6%. The proposed method was applied for the determination of the analytes in soybean, canola and sunflower oils.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.