Chemical Coagulation (CC) and Electrocoagulation (EC) processes using iron as coagulating agent were compared while treating aquifer water contaminated by a relatively high concentration of total chromium (CrT =19.0 mg L-1). A continuous semipilot comprising of EC (or CC), followed by flocculation, sedimentation and sandfiltration steps was used to remove CrT from water in order to get drinking water. A ratio of Fe/CrT ≥ 3 was required to reach the best efficiency of treatment using EC and CC. More than 99% of CrT was removed and residual CrT concentration below 0.05 mg L-1 (the limiting value recommended by WHO) could be obtained using the both configurations. However, CC increased the concentration of dissolved solids above the guideline recommended for drinking water.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.