When planning a CBCT service for children and young people, a limited FoV machine would be the appropriate choice for the majority of clinical requirements. It would facilitate clinical evaluation of scans, would limit the number of incidental findings and contribute to optimisation of radiation doses.
Objective: The aim of this study was to develop a low-dose protocol suitable for cone beam CT (CBCT) examination of an impacted maxillary canine in children by using a combination of dosimetry with subjective and objective image quality assessment.Methods: Radiation dose and image quality measurements were made using a dental CBCT machine. An image quality phantom was used to investigate the relationship between objective image quality and dosearea product (DAP) for a broad range of exposure settings. Subjective image quality assessment was achieved using a paediatric skull phantom submerged in a water bath for the same range of exposure settings. Eight clinicians assessed each CBCT data set for nine aspects of image quality using a five-point rating scale of agreement.
PurposeTo analyze cone-beam computed tomography (CBCT) use, indications, and exposure parameters in San José, Costa Rica.Materials and MethodsA cross-sectional study was performed. All CBCT examinations over a period of 6 months at 2 radiological centers in San José, Costa Rica were evaluated. The examinations were performed with Veraview EPOC X550 and Veraviewepocs 3D R100 equipment. The patients' age and sex, clinical indication for CBCT, region of interest (ROI), repeat examinations, specialty of the referring dentist, field-of-view (FOV), tube voltage (kV), tube current (mA), and radiation dose (µGy) were evaluated. Patients were classified by age as children (≤12 years), adolescents (13–18 years), and adults (≥19 years).ResultsThe mean age of the 526 patients was 49.4 years. The main indications were implant dentistry and dental trauma. The most frequent ROIs were posterior, while anterior ROIs were much less common. The highest percentage of repeat examinations was in children. Fifty-six percent of the referring dentists were specialists. The most commonly used FOV was small. The mean tube voltage and current were 79.8 kV and 7.4 mA for Veraview EPOC X550 and 89.9 kV and 6 mA for Veraviewepocs 3D R100, respectively. The mean doses for children, adolescents, and adults were 6.9 µGy, 8.4 µGy, and 7.8 µGy, respectively.ConclusionAlthough CBCT was most commonly used in adults for implant dentistry, most repeat examinations were in children, and the highest mean dose was in adolescents. Additional dose optimization efforts should be made by introducing low-dose protocols for children and adolescents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.