Pneumatic driven high pressure pumps (PDHPPs), having a number of considerable advantages in comparison to other types of high pressure pumps, are widely used in different sectors of modern industry. However, estimating the performance characteristics of a PDHPP is complicated due to the specifics of physical processes taking place during its operation. A mathematical model was developed to solve this problem. Two main operating modes are considered: for constant load and for constant volume, which cover the most common uses of the PDHPPs. The solution of the model made it possible to estimate how various parameters affect the operation of the pump. Thus, with an increasing pressure of compressed air, the volume flow grows at the pump outlet; with a higher pressure of the pumped liquid due to compressibility and a higher load on the drive cylinder, the flow, on the contrary, reduces. In case the PDHPP operates for the constant volume, the time of pressure increase grows with an increase of the required pressure and the value of this volume. The mathematical model and computational data can be used in the development of new and modification of the existing pumps.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.