Sepsis is the most frequent cause of death in the intensive care unit (ICU). A rapid and correct diagnosis and initiation of therapy is crucial for improving patient outcomes. The aim of this study was to compare the performance of calprotectin with the more widely used sepsis biomarker procalcitonin (PCT) in ICU patients. The performance of calprotectin and PCT as sepsis and prognostic markers for 30-d mortality was compared in a prospective, observational study in an eight-bed ICU. We investigated concentrations of the biomarkers in plasma collected at admission from all ICU patients admitted during a year (2012-2013, n ¼ 271) together with simplified acute physiology 3 scores (SAPS3) and sequential organ failure assessment (SOFA) scores. The receiver operating characteristic (ROC) analysis showed a higher area under the curve (AUC) value for calprotectin (0.79) than for PCT (0.49) when used as a sepsis marker. The calprotectin concentrations at admission were higher in non-survivors than in survivors at day 30. In our study, calprotectin was superior to PCT for distinguishing between ICU patients with sepsis and non-sepsis patients. Calprotectin also had higher predictive ability regarding 30-d mortality.
Cellsorba™ is a medical device for leukocytapheresis (LCAP) treatment of ulcerative colitis (UC). Cellsorba™ EX Global type has been developed from Cellsorba E for intended use with ACD-A as anticoagulant. We evaluated safety and efficacy of the modified Cellsorba using ACD-A in a pilot trial comprising patients with active UC, despite receiving 5-ASA. A total of 10 LCAP treatments/patients were administered. Safety assessment focused on clinical signs and symptoms, hematological variables, as well as levels of bradykinin and IL-6. Efficacy was determined using the Mayo clinical/endoscopic scoring index as well histological assessment of biopsies. Additional aim was to evaluate the impact of apheresis system lines and filter on selected regulatory molecules. All six subjects completed the trial without any serious adverse events. WBC, platelet counts, and levels of bradykinin and IL-6 were not significantly affected. The median Mayo score decreased from 8.0 to 3.5 at week 8 (and to 2 at week 16 for the responders). Four patients were responders, of whom two patients went into remission. Median histological scores decreased from 3.5 to 2.0 in these four patients. Concentration of LL-37 increased within the apheresis system lines. LCAP with Cellsorba EX using ACD-A as anticoagulant was found to be a safe and well-tolerated procedure in patients with active UC. The positive impact on efficacy parameters merits further evaluation in a controlled fashion.
Running the BÜHLMANN fCAL® turbo on Mindray BS-200E or cobas® c111 chemistry analyzers can provide rapid test results without exposing large routine chemistry analyzers to stool samples.
Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R= .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R= .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.