Decarbonizing heating in buildings is a key part of climate change mitigation policies, but deep retrofit is progressing slowly, e.g., at a pace of 0.2%/y of the building stock in Europe. By means of tests in two flats of a multiapartment housing complex recently renovated to very low values of energy needs, this paper explores the role of deep retrofitted buildings in providing energy flexibility services for the occupants/owners/managers and for the energy system. Key to this flexibility increase and capacity savings is the large reduction of energy needs for heating via a high level of external insulation, which allows the thermal capacity of the building mass to act as an energy storage, without the large energy losses presently affecting a large part of the building stock. Due to the limited number of case studies reporting experimental applications in real buildings, this research aims to offer an analysis based on a series of tests and detailed monitoring which show a significant increase in the time interval during which the low-energy-needs building remains in the comfort range, compared to a high-energy-needs building, when active delivery of energy is deactivated during the heating season. Intermittent renewable energy might hence be stored when available, thus enhancing the ability of the energy system to manage inherent variability of some renewable energy sources and/or increasing the share of the self-consumption of locally generated RES energy. Besides, two unplanned heating power outages which have involved the entire building complex allowed us to verify that deep retrofitted buildings are able to maintain thermally safe indoor conditions under extreme events, such as a power outage, for at least 5 days.
The article describes detailed measurements of indoor environmental parameters in a multiapartment housing block located in Milan, Italy, which has recently undergone a deep energy retrofit and is used as a thermal battery during the winter season. Two datasets are provided: one refers to a series of experimental tests conducted by the authors in an unoccupied flat, in which the thermal capacity of the building mass is exploited to act as an energy storage. The dataset reports, with a time step of 10 min, measurements of air temperature, globe temperature and surface temperatures in the analyzed room and data characterizing the adjacent spaces and the outdoor conditions. The second set of data refers to the air temperature monitoring carried out continuously in all the apartments of the apartment block, and hence also during two unplanned heating power outages. The analyzed data show the role of deep renovations in extending the time over which a building can remain in the thermal comfort range after an energy interruption and thus highlight the potential role of retrofitted buildings in delivering energy flexibility services to related stakeholders, such as the occupants, the building manager, the grid operator, and others. Furthermore, the dataset can be used to calibrate an energy simulation model to investigate different demand-side flexibility strategies and evaluate thermal safety under extreme weather events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.