Computer aided implantology is the safest way to perform dental implants. The research of high accuracy represents a daily effort. The validated method to assess the accuracy of placed dental implants is the superimposition of a pre-operative and a post-operative cone beam computed tomography (CBCT) with planned and placed implants. This procedure is accountable for a biologic cost for the patient. To investigate alternative procedure for accuracy assessment, fifteen resin casts were printed. For each model, six implants were digitally planned and then placed following three different approaches: (a) template guided free hand, (b) static computer aided implantology (SCAI), and (c) dynamic computer aided implantology (DCAI). The placement accuracy of each implant was performed via two methods: the CBCT comparison described above and a matching between implant positions recovered from the original surgical plan with those obtained with a post-operative intraoral scan (IOS). Statistically significant mean differences between guided groups (SCAI and DCAI) and the free hand group were found at all considered deviations, while no differences resulted between the SCAI and DCAI approaches. Moreover, no mean statistically significant differences were found between CBCT and IOS assessment, confirming the validity of this new method.
Periapical implantitis (IPL) is an increasingly frequent complication of dental implants. The causes of this condition are not yet entirely clear, although a bacterial component is certainly part of the etiology. In this case series study, two approaches will be described: because of persistent IPL symptoms, a patient had the implant removed and underwent histological analysis after week 6 from implantation. The histomorphometric examination revealed a 35% bone-implant contact area involving the coronal two-thirds of the implant. The apical portion of the fixture on the other hand was affected by an inflammatory process detectable on radiography as a radiolucent area. The presence of a probable root fragment, detectable as an imprecise radiopaque mass in the zone where the implant was later placed, confirms the probable bacterial etiology of this case of IPL. On the other hand, in case number 2, the presence of IPL around the fixture was solved by surgically removing the implant apical third as well as the adjacent tooth apex. It may be concluded from our histological examination that removal of the apical portion of the fixture should be considered an effective treatment for IPL since the remaining implant segment remains optimally osseointegrated and capable of continuing its function as a prosthetic abutment. Careful attention, however, is required at the implantation planning stage to identify in advance any sources of infection in the edentulous area of interest which might compromise the final outcome.
Achieving adequate fixation of bone blocks harvested from the mandibular symphysis and used in conjunction with dental implants has been a continuing challenge. In response, the Authors developed a method of using the implant itself to stabilize the graft material in single-implant sites in severely resorbed alveolar ridges. This technique was utilized to place 19 standard implants in 15 patients. After 12 to 60 months of clinical and radiological follow-up, all implants had survived, a success rate of 100%. Measurements of the radiographs showed bone loss of 1.70 mm ± 0.4 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.