This study aimed to develop and assess the psychometric properties of an English language measure of problematic mobile phone use. Participants were recruited from a university campus, health science center, and other public locations. The sample included 244 individuals (68.4% female) aged 18–75. Results supported a unidimensional factor structure for the 20-item self-report Problematic Use of Mobile Phones (PUMP) Scale. Internal consistency was excellent (α = 0.94). Strong correlations (r = .76, P < .001) were found between the PUMP Scale and an existing scale of cellular phone dependency that was validated in Asia, as well as items assessing frequency and intensity of mobile phone use. Results provide preliminary support for the use of the PUMP Scale to measure problematic use of mobile phones.
Structured reporting of CTE for IBD improved documentation of key reporting features for trainees and faculty, though there was minimal impact on accuracy. Referring physicians subjectively preferred the structured reports.
Purpose:To develop, in a phantom environment, a method to obtain multidetector computed tomographic (CT) data sets at multiple radiation exposure levels within the same patient and to validate its use for potential dose reduction by using different image reconstruction algorithms for the detection of liver metastases.
Materials andMethods:The American College of Radiology CT accreditation phantom was scanned by using a dual-source multidetector CT platform. By adjusting the radiation output of each tube, data sets at six radiation exposure levels (100%, 75%, 50%, 37.5%, 25%, and 12.5%) were reconstructed from two consecutive dual-source single-energy (DSSE) acquisitions, as well as a conventional single-source acquisition. A prospective, HIPAA-compliant, institutional review boardapproved study was performed by using the same DSSE strategy in 19 patients who underwent multidetector CT of the liver for metastatic colorectal cancer. All images were reconstructed by using conventional weighted filtered back projection (FBP) and sinogramaffirmed iterative reconstruction with strength level of 3 (SAFIRE-3). Objective image quality metrics were compared in the phantom experiment by using multiple linear regression analysis. Generalized linear mixed-effects models were used to analyze image quality metrics and diagnostic performance for lesion detection by readers.
Results:The phantom experiment showed comparable image quality between DSSE and conventional single-source acquisition. In the patient study, the mean size-specific dose estimates for the six radiation exposure levels were 13.0, 9.8, 5.8, 4.4, 3.2, and 1.4 mGy. For each radiation exposure level, readers' perception of image quality and lesion conspicuity was consistently ranked superior with SAFIRE-3 when compared with FBP (P .05 for all comparisons). Reduction of up to 62.5% in radiation exposure by using SAFIRE-3 yielded similar reader rankings of image quality and lesion conspicuity when compared with routine-dose FBP.
Conclusion:A method was developed and validated to synthesize multidetector CT data sets at multiple radiation exposure levels within the same patient. This technique may provide a foundation for future clinical trials aimed at estimating potential radiation dose reduction by using iterative reconstructions.q RSNA, 2016
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.