A 48-year-old man presented with hyphema, iridocyclitis, iridophacodonesis, and maculopathy after a contusive trauma. Ultrasound biomicroscopy identified a 90-degree cyclodialysis cleft with severe damage of the zonular fibers. Echographic B-scan examination revealed intravitreal hemorrhage and a 360-degree choroidal detachment. One month later, phacoemulsification was performed and a single-piece poly(methyl methacrylate) intraocular lens was inserted into the ciliary sulcus, with the haptic rotated toward the cyclodialysis cleft area. Postoperatively, the visual acuity improved and the intraocular pressure returned to normal. Ultrasound biomicroscopy showed closure of the cleft by reattachment of the ciliary body to the scleral spur. Optical coherence tomography revealed complete resolution of the macular and choroidal folds. Ultrasound biomicroscopy is a useful method for appropriate management of traumatic cyclodialysis cleft. In cases of small cyclodialysis clefts, with the surgical method we describe, the lens haptics apply directional force toward the sclera, fostering adherence of the ciliary body fibers.
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.Keratoconus is an eye disorder that causes the cornea to take an abnormal conical shape, thus impairing its refractive functions and causing blindness. The late diagnosis of keratoconus is among the principal reasons for corneal surgical transplantation. This pathology is characterized by a reduced corneal stiffness in the region immediately below Bowman's membrane, probably due to a different lamellar organization, as suggested by previous studies. Here, the lamellar organization in this corneal region is characterized in three dimensions by means of secondharmonic generation (SHG) microscopy. In particular, a method based on a three-dimensional correlation analysis allows to probe the orientation of sutural lamellae close to the Bowman's membrane, finding statistical differences between healthy and keratoconic samples. This method is demonstrated also in combination with an epi-detection scheme, paving the way for a potential clinical ophthalmic application of SHG microscopy for the early diagnosis of keratoconus.SHG image acquired with sagittal optical sectioning (A) of a healthy cornea and (B) of a keratoconic cornea. Scale bars: 30 μm.
We report the neurophysiological findings from 24 subjects with myotonic dystrophy of Steinert and the histological findings in two of them. The conduction data is compared with that of a group of subjects with Landouzy‐Déjérine muscular dystrophy. In 46% of cases, the electrophysiological data revealed slight and generalized axonal neuropathy. Histological results of sural nerve confirmed axonal damage of sensory fibres. The neuropathy was not correlated with age of patients, duration or onset of the disease, nor with the state of the deep reflexes; it did not show signs of progressing and is probably one of the multisystemic manifestations of gene pleiotropism.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.