Background and Purpose Stroke is the leading cause of long term disability in the United States, and for many it causes loss of gait function. The purpose of this research is to examine stroke survivors’ gait adaptations to training on the Powered Ankle Foot Orthosis (PAFO). Of particular interest is the stroke survivors’ ability to learn how to store and release energy properly while using the device. The PAFO utilizes robotic tendon technology and supports motion with a single degree of freedom, ankle rotation in the sagittal plane. This actuator comprises a motor and series spring. The user interacts with the output side of the spring while the robot controls the input side of the spring such that typical able body ankle moments would be generated, assuming able body ankle kinematics are seen at the output side of the spring. Methods Three individuals post-stroke participated in a three week training protocol. Outcome measures (temporal, kinematic, and kinetic) were derived from robot sensors and recorded for every step. These data are used to evaluate each stroke survivor’s adaptations to robotic gait assistance. The robot was worn only on the paretic ankle. For validation of the kinematic results, motion capture data were collected on the third subject. Results All subjects showed increased cadence, ankle range of motion, and power generation capabilities. Additionally, all subjects were able to achieve a larger power output than power input from the robot. Motion capture data collected from subject three validated the robot sensor kinematic data on the affected side, but also demonstrated an unexpected gait adaptation on the unaffected ankle. Conclusions Sensors on the gait assisting robot provide large volumes of valuable information on how gait parameters change over time. We have developed key gait evaluation metrics based on the available robot sensor information that may be useful to future researchers. All subjects adapted their gait to the robotic assistance, and many of their key metrics moved closer to typical able body values. This suggests that each subject learned to utilize the assistive moments generated by the robot, despite having no predefined ankle trajectory input from the robot. The security of being harnessed on the treadmill led to more dramatic and favorable results.
Passive prosthetic feet are not able to provide non-amputee kinematics and kinetics for the ankle joint. Persons with amputations show reduced interlimb symmetry, slower walking speeds, and increased walking effort. To improve ankle range of motion and push off, various powered prosthetic feet were introduced. This feasibility study analyzed if predefined motor reference trajectories can be used to achieve non-amputee ankle biomechanics during walking with the powered prosthetic foot, Walk-Run Ankle. Trajectories were calculated using the desired ankle angle and ankle moment based spring deflection at a given spring stiffness. Model assumptions of the motor-spring interaction were well reflected in the experiment. The powered foot was able to improve range of motion, peak ankle power, average positive ankle power, peak ankle moment, and positive moment onset compared to a passive usage of the foot. Furthermore, symmetry improvements were identified for step length and duty factor. Further studies with an increased number of subjects are needed to show if the approach is also valid for other amputees. Using this method as a base, trajectories can be further individualized using human in the loop optimization targeting a reduction of user effort, improved stability, or gait symmetry.
Back pain is one of the largest drivers of workplace injury and lost productivity in industries around the world. Back injuries were one of the leading reasons in resulting in days away from work at 38.5% across all occupations, increasing for manual laborers to 43%. While the cause of the back pain can vary across occupations, for materiel movers it is often caused from repetitive poor lifting. To reduce the issues, the Aerial Porter Exoskeleton (APEx) was created. The APEx uses a hip-mounted, powered exoskeleton attached to an adjustable vest. An onboard computer calculates the configuration of the user to determine when to activate. Lift form is assisted by using a novel lumbar brace mounted on the sides of the hips. Properly worn, the APEx holds the user upright while providing additional hip torque through a lift. This was tested by having participants complete a lifting test with the exoskeleton worn in the “on” configuration compared with the exoskeleton not worn. The APEx has been shown to deliver 30 Nm of torque in lab testing. The activity recognition algorithm has also been shown to be accurate in 95% of tested conditions. When worn by subjects, testing has shown average peak reductions of 14.9% BPM, 8% in VO2 consumption, and an 8% change in perceived effort favoring the APEx.
Spring-based actuators are important in the design of wearable robotic systems. These actuators can store and release energy, and reduce the peak power requirements. Reducing these requirements allows the system to function with smaller and lighter-weight motors. Three actuators are compared: a lead screw actuator, a robotic tendon actuator, and a JackSpring TM actuator. The robotic tendon actuator adds a spring in series to the traditional actuator. The JackSpring actuator is a lead screw with a finite stiffness. A formal set of equations for the three actuators is added to Table 1 which summarizes the torque, angular speed, and power for each one. The traditional lead screw actuator cannot store and release energy and the power into the actuator must equal the power out of the actuator. The robotic tendon actuator stores and releases energy, and if a tuned spring is chosen, the power requirements can be greatly reduced. For example, if the desired external motion matches the natural frequency of the system, the motor does not need to rotate. The JackSpring actuator is a unique actuator because the stiffness and motion are coupled. It is shown that if the spring is tuned properly, the power requirements can be greatly reduced, as well.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.