The lithium-sulfur (Li-S) cell system is promising to satisfy the increasing need for cost-efficient energy storage with high theoretical energies due to the enormous theoretical gravimetrical capacity and the abundance of sulfur. Furthermore, the technology readiness level of Li-S batteries increased steadily in recent years due to extensive research, as well as the number of reported prototype cells. However, an often ignored test parameter is the application of external pressure to the cell stack. In this study, the influence of external pressure on the performance of Li-S cells is investigated. Therefore, five-layered pouch cells with solvent-free processed cathodes are assembled. These cells are tested under lean electrolyte conditions (electrolyte to sulfur ratio of 4.5 µl mg(S)−1). To evaluate the influence of the used electrolyte system either the state-of-the-art 1,2-dimethoxyethane/1,3-dioxolane electrolyte or the sparing polysulfide solvating hexyl methyl ether/1,3-dioxolane electrolyte is deployed. The impact of pressure application is evaluated electrochemically as well as by post-mortem focused ion beam-scanning electron microscopy of the cycled electrodes. Moreover, a technique for infiltration of sulfur into the carbon host matrix is presented, discussed, and successfully implemented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.