To investigate how, and to what extent, the following factors influence burn damage: (1) the angle of application of the ignition source to the sample surface, and (2) the flow rate for the ignition source, when assessing samples in accordance with ISO 8191-2:1988. Varying the ignition source flow rate and the angle of application of the ignition source to the sample undergoing testing, which are both variations on the existing procedure outlined in the Standard ISO 8191-2:1988. Burn damage as measured by the depth (if applicable) and greatest horizontal and vertical dimensions. Increasing the ignition source gas flow rate (from 45 ml/min to 240 ml/min) increased the measured burn damage for both foam and vinyl samples. The increased damage factor was at least two-fold (and up to five-fold). Changing the angle of application of the ignition source (45 degrees compared to 0 degrees) did not significantly affect the measured burn damage for either sample. These findings indicate that the direction of application of a match-flame equivalent ignition source has no significant affect on the resulting burn damage, but that increasing the ignition source flow rate increases the burn damage for both foam and vinyl samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.