The suitability of different gelling agents as MRI phantoms was evaluated in terms of homogeneity, gel stability and reproducibility. Time and effort for preparation were also taken into account. The relaxation times of various gel compositions were estimated. Carbomer-980 and Carbopol-974P were determined to be promising novel phantom materials. These gelling agents are readily available, inexpensive and easy to handle given that thermal treatment is not required. Furthermore, the viscoelasticity of their polymer network is pH-dependent. With such characteristics, it was even possible to embed sensitive objects and retrieve them after testing. This was demonstrated with a fiber phantom for Diffusion Weighted MRI applications. Since Carbomer-980 and Carbopol-974P are non-hazardous, they are also suitable for multimodal setups (e.g., MRI as well as ultrasonic imaging).
Background: Directional deep brain stimulation (DBS) allows steering the stimulation in an axial direction which offers greater flexibility in programming. However, accurate anatomical visualization of the lead orientation is required for interpreting the observed stimulation effects and to guide programming. Objectives: In this study we aimed to develop and test an accurate and robust algorithm for determining the orientation of segmented electrodes based on standard postoperative CT imaging used in DBS. Methods: Orientation angles of directional leads (CartesiaTM; Boston Scientific, Marlborough, MA, USA) were determined using CT imaging. Therefore, a sequential algorithm was developed that quantitatively compares the similarity of the observed CT artifacts with calculated artifact patterns based on the lead’s orientation marker and a geometric model of the segmented electrodes. Measurements of seven ground truth phantoms and three leads with 60 different configurations of lead implantation and orientation angles were analyzed for validation. Results: The accuracy of the determined electrode orientation angles was –0.6 ± 1.5° (range: –5.4 to 4.2°). This accuracy proved to be sufficiently high to resolve even subtle differences between individual leads. Conclusions: The presented algorithm is user independent and provides highly accurate results for the orientation of the segmented electrodes for all angular constellations that typically occur in clinical cases.
The results show that both imaging modalities can be used to determine lead orientation angles with high accuracy. CT is superior to x-ray imaging, but oblique leads (polar angle > 40°) show limited precision due to the current design of the directional marker.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.