Background The most common first-line fixation technique for simple Weber B fibula fractures is a lag screw with lateral neutralization plate. The most common surgical technique for unstable Weber B fibula fracture is one-third semi-tubular plate and cortical screws, implemented with lag screw when appropriate. However, the lag technique can be technically challenging in osteoporotic bone or within fibulas of smaller diameter, and in some cases can result in fragmentation at the fracture site, malreduction, or peroneal irritation. The purpose of this study is to examine an alternative first-line method for routine treatment of simple Weber B fibula fractures. Methods Fifty-two consecutive patients undergoing open reduction internal fixation (ORIF) of a Weber B fibula fracture by a single surgeon were included in this retrospective study. After reduction, a lateral locking plate was applied with cortical screws proximally and locking screws distally. No screw crossed the fracture in any case. Per published precedent, nonunion was defined as either a gap of >3 mm between fracture surfaces >6 months postoperatively or a fracture line >2 to 3 mm wide and sclerosing of the fracture surfaces. Similarly, malunion was defined as one or more of the following: talar tilt >2º, talar subluxation >2 mm, or tibiofibular clear space ≥5 mm. Results The mean (± standard deviation) age of the 52 included patients was 44.2 ± 16.2 years, the mean body mass index was 27.7 ± 6.6 kg/m2, and 63.5% of patients identified themselves as female sex. The mean follow-up was 6.2 (range: 1.5-15) months. In addition to undergoing fixation of the lateral malleolus, 21 patients also underwent fixation of the posterior malleolus, 27 underwent fixation of the medial malleolus, 29 underwent fixation across the syndesmosis, and 7 underwent repair of the deltoid. In all patients, bony anatomic union of the fibula and congruence of the mortise were achieved with no cases of malunion or nonunion. Conclusions The Arbeitsgemeinschaft für Osteosynthesefragen (AO) fixation technique for simple Weber B fractures with a lag screw and lateral neutralization plating has provided good outcomes for decades. We present an alternative technique for ORIF of these fractures with a lateral locking plate and no lag screw. In our series, we evaluated radiographic union and alignment as our primary outcome measures and found no cases of nonunion or malunion. Prospective cohort testing of lateral locking plates versus traditional fixation in the context of patient-centered value is warranted. Level of Evidence: Level III
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.