Sudden death is one of the more frequent causes of death for hemodialysis patients, but the underlying mechanisms, contribution of arrhythmia, and associations with serum chemistries or the dialysis procedure are incompletely understood. To study this, implantable loop recorders were utilized for continuous cardiac rhythm monitoring to detect clinically significant arrhythmias including sustained ventricular tachycardia, bradycardia, asystole, or symptomatic arrhythmias in hemodialysis patients over six months. Serum chemistries were tested pre- and post-dialysis at least weekly. Dialysis procedure data were collected at every session. Associations with clinically significant arrhythmias were assessed using negative binomial regression modeling. Sixty-six patients were implanted and 1678 events were recorded in 44 patients. The majority were bradycardias (1461), with 14 episodes of asystole and only one of sustained ventricular tachycardia. Atrial fibrillation, although not defined as clinically significant arrhythmias, was detected in 41% of patients. With thrice-weekly dialysis, the rate was highest during the first dialysis session of the week and was increased during the last 12 hours of each inter-dialytic interval, particularly the long interval. Among serum and dialytic parameters, only higher pre-dialysis serum sodium and dialysate calcium over 2.5 mEq/L were independently associated with clinically significant arrhythmias. Thus, clinically significant arrhythmias are common in hemodialysis patients, and bradycardia and asystole rather than ventricular tachycardia may be key causes of sudden death in hemodialysis patients. Associations with the temporal pattern of dialysis suggest that modification of current dialysis practices could reduce the incidence of sudden death.
Among patients whose physicians reviewed recommendations of the decision support tool discordant therapy decreased significantly over 1 year. However, in nonstratified analyses, the intervention did not result in significant improvements in discordant antithrombotic therapy.
Even with experienced operators complications can occur when replacing generators for a device recall. Careful risk assessment for each individual patient should be performed and efforts made to minimize generator changes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.