DEB-DOX results, with high rates of 5-year survival for patients, not amenable to curative treatments. Number of lesions, lesion vascularity, and local response were significant independent determinants of 5-year survival.
The purpose of this study was to assess the safety and efficacy of doxorubicin-loaded beads (DC Beads) delivered by transarterial embolization for the treatment of unresectable hepatocellular carcinoma (HCC). This open-label, single-center, single-arm study included 62 cirrhotic patients with documented single unresectable HCC. Mean tumor diameter was 5.6 cm (range, 3-9 cm) classified as Okuda stages 1 (n = 53) and 2 (n = 9). Patients received repeat embolizations with doxorubicin-loaded beads every 3 months (maximum of three). The maximum doxorubicin dose was 150 mg per embolization, loaded in DC Beads of 100-300 or 300-500 microm. Regarding efficacy, overall, an objective response according to the European Association for the Study of the Liver criteria was observed in 59.6%, 81.8%, and 70.8% across three treatments. A complete response was observed in 4.8% after the first procedure and 3.6% and 8.3% after the second and third procedures, respectively. At 9 months a complete response was seen in 12.2%, an objective response in 80.7%, progressive disease in 6.8%, and 12.2% showed stable disease. Mean tumor necrosis ranged from 77.4% to 83.9% (range, 28.6%-100%) across three treatments. alpha-Fetoprotein levels showed a mean decrease of 1123 ng/ml (95% CI = 846-1399; p = 3 x 10(-11)) after the first session and remained stable after the second and third embolizations (42 and 70 ng/ml decrease, respectively). Regarding safety, bilirubin, gamma-glutamyl transferase, aspartate aminotransferase, alanine aminotransferase, and alkaline phosphatase showed only transient increases during the study period. Severe procedure-related complications were seen in 3.2% (cholecystitis, n = 1; liver abscess, n = 1). Postembolization syndrome was observed in all patients. We conclude that hemoembolization using doxorubicin-loaded DC Beads is a safe and effective treatment of HCC as demonstrated by the low complication rate, increased tumor response, and sustained reduction of alpha-fetoprotein levels.
BackgroundThis study examined the safety, pharmacokinetics, and efficacy of transarterial chemoembolization of hepatocellular carcinoma (HCC) using a newly developed size of a superabsorbent polymer drug-eluting embolic material.MethodsForty-five patients with documented HCC (Child–Pugh score A/B: 55.5 %/44.5 %) were embolized with HepaSphere microspheres 30–60 μm with escalation of lesion, dose, and frequency of re-embolization. Local response was evaluated with modified response evaluation criteria in solid tumors (mRECIST). Plasma levels of doxorubicin were measured in 24 patients at baseline and at 5, 20, 40, 60, and 120 min, at 6, 24, and 48 h, and at 7 days, respectively, to determine doxorubicin in plasma (Cmax) and area under the curve (AUC). Measurements of three patients who underwent lipiodol-based conventional chemoembolization (c-TACE) were also performed.ResultsTACE with HepaSphere was well tolerated with an acceptable safety profile and no 30-day mortality. Response rates were calculated on intention-to-treat basis with complete response (CR) in 17.8 % reaching 22.2 % for the target lesion. Overall partial response (PR) was seen in 51.1 %, stable disease in 20 %, and progressive disease in 11.1 % of patients. Overall objective response (CR + PR), including patients treated at all dosages of doxorubicin, was seen in 68.9 % of cases. After a median follow-up of 15.6 months, 1-year survival is 100 %. Doxorubicin AUC was significantly lower in patients with HepaSphere 30–60 μm (35,195 ± 27,873 ng × min/ml) than in patients with conventional TACE (103,960 ± 16,652 ng × min/ml; p = 0.009). Cmax was also significantly lower with HepaSphere 30–60 μm (83.9 ± 32.1 ng/ml) compared with c-TACE (761.3 ± 58.8 ng/ml; p = 0.002).ConclusionHepaSphere 30–60 μm is an effective drug-eluting embolic material with a favourable pharmacokinetic profile.
Percutaneous augmented peripheral osteoplasty (rebar concept) for symptomatic malignant lesions in long bones seems to be a possible new technique for bone stabilization. This combination seems to provide necessary stability against shearing forces applied in long bones during weight bearing.
Initial evidence shows that (a) TANDEM™ achieves high rates of local response and mid-term survival, (b) high loading provides no clinical benefit and is associated with biliary toxicity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.