The study demonstrated that hypoxia and variations of atmospheric pressure may produce corneal edema, including changes of CCT and, correlatively, CS reduction.
This is a double-blind, placebo-controlled study of the efficacy, safety, and tolerability of sibutramine in the management of obese patients for a 6-month period.METHOD: Sixty-one obese patients (BMI >30, <40 kg/m2), aged 18-65 years were evaluated. In the first phase of the study (30 days), the patients were given a placebo. We monitored compliance with a low-calorie diet (1200 kcal/day) and to the placebo. In the next stage, the double-blind phase (6 months), we compared placebo and sibutramine (10 mg/day). The criteria for evaluating efficacy were weight loss, reduction in body mass index (BMI), and abdominal and hip circumferences. Tolerability was assessed based on reported side effects, variation in arterial blood pressure and heart rate, metabolic profile (fasting glucose, total cholesterol and its fractions, and triglycerides), laboratory tests (renal and hepatic functions), and flow Doppler echocardiogram. RESULTS:We observed a greater weight loss (7.3 kg, 8% vs 2.6 kg, 2.8%) and a reduction in body mass index (7.4% vs 2.1%) in the sibutramine group than in the placebo group. Classifying the patients into 4 subgroups according to weight loss (weight gain, loss <5%, loss of 5% to 9.9%, and loss >10%), we observed a weight loss of >5% in 40% of the patients on sibutramine compared with 12.9% in the placebo group. We also detected weight gain in 45.2% of the placebo group compared to 20% in the sibutramine group. The sibutramine group showed improvement in HDL-cholesterol values (increased by 17%) and triglyceride values (decreased by 12.8%). This group also showed an increase in systolic blood pressure (6.7%, 5 mmHg). There were no changes in echocardiograms comparing the beginning and end of follow-up, and side effects did not lead to discontinuation of treatment.DISCUSSION: Sibutramine proved to be effective for weight loss providing an 8% loss of the initial weight. Compliance to prolonged treatment was good, and side effects did not result in discontinuation of treatment. These data confirmed the good efficacy, tolerability, and safety profiles of sibutramine for treatment of obesity. DESCRIPTORS: Obesity. Weight loss. Sibutramine.
Pierin AMG, Ignez EC, Jacob Filho W, Barbato AJG, Mion Jr. D. Blood pressure measurements taken by patients are similar to home and ambulatory blood pressure measurements. Clinics. 2008;63(1):43-50. OBJECTIVE:To compare blood pressure measurements taken at home by physicians, nurses, and patients with office blood pressure measurement , ambulatory blood pressure monitoring and home blood pressure measurement. METHODS: A total of 44 patients seen by a home care program were studied. Protocol 1 a) blood pressure was measured by the patient, a physician and a nurse during a regular home visit (Home1); b) home blood pressure measurement was measured for 4 days (HBPM1); c) office blood pressure measurement was measured by a physician, a nurse, and the patient; and by 24-hour ambulatory blood pressure monitoring. Protocol 2 blood pressure was measured by the patient, a physician, and a nurse during a special home visit in the presence of a physician and a nurse only (Home2); and b) home blood pressure measurement was taken for the second time (HBPM2). Echocardiography, guided by a two-dimensional echocardiograph, was performed. RESULTS: Protocol 1: a) office blood pressure measurement and Home1 were significantly higher than ambulatory blood pressure monitoring, except for systolic and diastolic office blood pressure measurement taken by the patient or a family member, systolic blood pressure taken by a nurse, and diastolic blood pressure taken by a physician. b) ambulatory blood pressure monitoring and HBPM1 were similar. Protocol 2: a) HBPM2 and Home2 were similar. b) Home2 was significantly lower than Home1, except for diastolic blood pressure taken by a nurse or the patient. There were significant relationships between: a) diastolic blood pressure measured by the patient and the thickness of the interventricular septum, posterior wall, and left ventricular mass; and b) ambulatory and HBPM2 diastolic and systolic blood pressure taken by a physician (home2) and left ventricular mass. Therefore, the data indicate that home blood pressure measurement and ambulatory blood pressure monitoring had good prognostic values relative to "office measurement." CONCLUSION: This study showed that the measurement most similar to home blood pressure measurement and ambulatory blood pressure monitoring was blood pressure measured by the patient, and that home blood pressure measurement and ambulatory blood pressure monitoring had good prognostic value relative to "office measurements". KEYWORDS:Home blood pressure. Ambulatory blood pressure. Office blood pressure measurement. Hypertension. White coat effect.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.