There is need for an in vitro diagnostic test for hypersensitivity to nonsteroidal anti-inflammatory drugs (NSAIDs). The purpose of this study was to assess the reliability of one such diagnostic, the basophil activation test. Forty-three drug hypersensitive patients referring several immediate reactions (anaphylaxis, urticaria, angioedema, asthma, and rhinoconjunctivitis) to one or more NSAIDs and 29 controls participated. Using the Basotest commercial kit, 63 determinations were performed with the drugs implicated in the adverse reactions (ASA, ibuprofen, metamizol, diclofenac, paracetamol, and ketorolac). In 16 patients additional determinations were made with other chemically unrelated NSAIDs. Forty-two determinations were made for controls. The analysis was performed by flow colorimetric cytometry and double staining with the monoclonal antibodies anti-IgE and anti-CD63. A Basophil Activation Index (percentage of activated basophils after allergen stimulation/percentage of basally activated basophils) of two or more was considered a positive result. Specificity of 100% and sensitivity of 42.85% were achieved. The positive predictive value was 100%, and the negative predictive value was 53.84%. In 35.29% of intolerant patients there was a positive reaction to at least two drugs implicated in adverse reactions, and in 27.27% of these patients there was a positive reaction to other chemically unrelated NSAIDs. The basophil activation test is useful for the in vitro diagnosis of NSAID hypersensitivity, providing good specificity and positive predictive value and diagnostic reliability in the assessment of NSAID intolerance.
In this paper, we introduce a bisexual Galton-Watson branching process with mating function dependent on the population size in each generation. Necessary and sufficient conditions for the process to become extinct with probability 1 are investigated for two possible conditions on the sequence of mating functions. Some results for the probability generating functions associated with the process are also given.
PurposeThe basophil activation test (BAT) has been used to monitor venom immunotherapy (VIT) due to its high specificity. A previous study has reported a good correlation between a significant decrease in basophil activation during 5 years of VIT and clinical protection assessed by sting challenge. The following prospective study was performed to examine changes in basophil reactivity over a complete VIT period of 5 years.MethodsBAT in a dose-response curve was studied prospectively in 10 hymenoptera venom-allergic patients over 5 years of VIT. BAT was performed at the time of diagnosis, 1 month after finishing the VIT build-up phase, and 3, 6, 12, 24, and 60 months after beginning treatment. The repeated measures ANOVA was applied to evaluate basophil activation changes throughout VIT. A cross-sectional study was also performed in 6 patients who received treatment for more than 3 years, and in another 12 patients who followed immunotherapy for at least 5 years.ResultsAn early activation decrease was observed during the first 3 months of treatment, compared to pre-treatment values. This activation decrease was not maintained 6 to 18 months after treatment, but was observed again after 2 years of treatment, and maintained until the completion of the 5-year immunotherapy period. In cross-sectional analysis, the 6 patients who received treatment for 3 years, and 9 of the 12 patients who received treatment for 5 years, had negative BAT results. Three patients in this last group had positive BAT results and 2 patients had systemic reactions after field stings.ConclusionsBAT appears to be an optimal non-invasive test for close monitoring of VIT.
In this paper, we introduce a bisexual Galton-Watson branching process with mating function dependent on the population size in each generation. Necessary and sufficient conditions for the process to become extinct with probability 1 are investigated for two possible conditions on the sequence of mating functions. Some results for the probability generating functions associated with the process are also given.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.