The use of bone marrow derived mesenchymal stromal cells (BMSC) in the treatment of alloimmune and autoimmune conditions has generated much interest, yet an understanding of the therapeutic mechanism remains elusive. We therefore explored immune modulation by a clinical-grade BMSC product in a model of human-into-mouse xenogeneic GVHD (x-GVHD) mediated by human CD4+ Th1 cells. BMSC reversed established, lethal x-GVHD through marked inhibition of Th1 cell effector function. Gene marking studies indicated BMSC engraftment was limited to the lung; further, there was no increase in regulatory T cells, thereby suggesting a paracrine mechanism of BMSC action. BMSC recipients had increased serum CD73 expressing exosomes that promoted adenosine accumulation ex vivo. Importantly, immune modulation mediated by BMSC was fully abrogated by pharmacologic therapy with an adenosine A2A receptor antagonist. To investigate the potential clinical relevance of these mechanistic findings, patient serum samples collected pre- and post-BMSC treatment were studied for exosome content: CD73 expressing exosomes promoting adenosine accumulation were detected in post-BMSC samples. In conclusion, BMSC effectively modulate experimental GVHD through a paracrine mechanism that promotes adenosine-based immune suppression.
Vagal efferent reinnervation can occur after orthotopic heart transplantation in humans. However, the absence of such reinnervation in some patients with vasovagal responses to tilt calls into question the role of left ventricular receptors in inducing the vasovagal reaction.
Objective-To evaluate a clinic set up specifically to assess patients with recent onset chest pain, particularly those presenting with a normal resting electrocardiogram.Design-Retrospective review of case notes.Setting-Cardiac department of a tertiary referral cardiothoracic centre.Patients-250 consecutive patients with recent onset chest pain seen within 24 hours of general practitioner referral.Outcome measures-Clinical diagnosis and management.Results-40% of patients were seen within seven days of the onset of symptoms. Twenty seven per cent had non-cardiac symptoms and could be discharged while 60% were considered to have cardiac pain. Sixty six patients (26%) were admitted directly from the clinic and 48 of these underwent coronary angiography within three weeks. Seventy patients (28%) have so far undergone intervention (angioplasty or coronary artery surgery), 22 within one month of presentation. One hundred and nine patients (44%) presented with a normal resting electrocardiogram, 21 of whom were considered to have unstable angina. Forty one of these patients were investigated of whom 37 were found to have significant coronary disease and 26 have undergone intervention.Conclusions-This experience highlights the inadequacy of a routine electrocardiogram reporting service in patients with recent onset of chest pain. An alternative facility offering immediate and complete cardiac assessment produced patient benefit with early diagnosis and intervention. Investigation of these patients, however, accounted for 5% of cardiac catheterisation laboratory throughput; this was a significant additional and unscheduled workload.
Introduction
Catheter stability during atrial fibrillation ablation is associated with higher ablation success rates. Rapid cardiac pacing and high‐frequency jet ventilation (HFJV) independently improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied. The objective of this study was to determine the effect of simultaneous heart rate and respiratory rate modulation on catheter stability.
Methods
Forty patients undergoing paroxysmal atrial fibrillation ablation received ablation lesions at 15 prespecified locations (12 left atria, 3 right atria). Patients were randomly assigned to undergo rapid atrial pacing for either the first or the second half of each lesion. Within each group, half of the patients received HFJV and the other half standard ventilation. Contact force and ablation data for all lesions were compared among the study groups. Standard deviation of contact force was the primary endpoint defined to examine contact force variability.
Results
Lesions with no pacing and standard ventilation had the greatest contact force standard deviation (5.86 ± 3.08 g), compared to lesions with pacing and standard ventilation (5.45 ± 3.28 g; P < .01) or to lesions with no pacing and HFJV (4.92 ± 3.00 g; P < .01). Lesions with both pacing and HFJV had the greatest reduction in contact force standard deviation (4.35 ± 2.81 g; P < .01), confirming an additive benefit of each maneuver. Pacing and HFJV together was also associated with a reduction in the proportion of lesions with excessive maximum contact force (P < .001).
Discussion
Rapid pacing and HFJV additively improve catheter stability. Simultaneous pacing with HFJV further improves catheter stability over pacing or HFJV alone to optimize ablation lesions.
Pacing induced heart rate acceleration reduces catheter-tissue contact variability, increases the probability of achieving pre-specified catheter-tissue contact endpoints, and enhances impedance reduction during ablation. Modulating heart rate to improve catheter-tissue contact offers a new approach to optimize lesion quality in AF ablation. (The Physiological Effects of Pacing on Catheter Ablation Procedures to Treat Atrial Fibrillation [PEP AF]; NCT02766712).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.