OBJECTIVEPostoperative subsidence of transforaminal lumbar interbody fusion (TLIF) cages can result in loss of lordosis and foraminal height, and potential recurrence of nerve root impingement. The objectives of this study were to determine factors associated with TLIF cage subsidence. Specifically, the authors sought to determine if preoperative disc height compared to cage height could be used to predict TLIF interbody cage subsidence, and if decreased postoperative vertebral Hounsfield units (HUs) predisposed to cage subsidence.METHODSThe authors retrospectively reviewed all patients undergoing instrumented TLIF from two institutions between July 2004 and June 2014. The preoperative disc height was measured for the operative and adjacent-level disc on MRI. The difference between cage and disc heights was measured and compared between the subsidence and nonsubsidence groups. The average HUs of the L1 vertebral body were measured on CT scans.RESULTSEighty-nine patients were identified with complete imaging and follow-up information. Forty-five patients (50.6%) had evidence of interbody cage subsidence on follow-up CT. The average cage subsidence was 5.5 mm (range 2.2–10.8 mm). The average implant height was significantly higher in the subsidence group compared to the nonsubsidence group (12.6 vs 11.2 mm). Additionally, the difference between cage height and preoperative adjacent-level disc height was also significantly larger in the subsidence group (3.8 vs 1.2 mm). First lumbar vertebral body (L1) HUs were significantly higher in the nonsubsidence versus the subsidence group (167.8 vs 137.71 HUs, p = 0.002). Multivariate logistic regression analysis identified suprajacent disc height and L1 HUs to be independent predictors of interbody cage subsidence. Receiver operating characteristic curves identified a suprajacent to cage height difference > 1.3 mm to have a 93.3% sensitivity for cage subsidence.CONCLUSIONSThis study is the first of its kind to demonstrate the association between vertebral body HUs and suprajacent disc height with the development of interbody cage subsidence after TLIF. The authors found that patients with lower HUs in the L1 vertebral body were more likely to experience subsidence, regardless of surgical level. Additionally, the study demonstrated that interbody cage height > 1.3 mm above the height of the suprajacent level is an independent risk factor for cage subsidence, with 93.3% sensitivity. These findings suggest that these factors may be utilized to create a template preoperatively for intraoperative cage selection.
Introduction: Although the role of intrasite antibiotic powder in preventing surgical site infections (SSIs) has been extensively explored in spinal surgery, it remains underevaluated in the other orthopaedic subspecialties. This systematic review examines the utilization of intrawound antibiotic powder as a prophylactic measure against SSIs in orthopaedic procedures. Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, electronic searches were conducted on Ovid MEDLINE, and PubMed. Only English language, nonspine clinical studies published before May 2018 were included. Results: The initial search identified 179 individual citations, and 11 studies met the eligibility criteria. All included studies were level III retrospective studies. Represented subspecialties included total joint arthroplasty, upper extremity, foot and ankle, and trauma. Eight studies demonstrated a statistically significant decrease in SSIs with the use of intrasite antibiotic powder. Discussion: There are no current guidelines for the use of intrasite antibiotic powder for the prevention of SSIs in orthopaedic procedures. Despite the lack of high-quality evidence available in the literature, published smaller studies do suggest a significant protective effect. However, recommendations with regard to this technique after common orthopaedic procedures cannot yet be made.
During the Global War on Terrorism, many US Military service members sustained injuries with potentially long-lasting functional limitations and chronic pain. We sought to understand the patterns of prescription opioid use among service members injured in combat. METHODS:We queried the Military Health System Data Repository to identify service members injured in combat between 2007 and 2011. Sociodemographics, injury characteristics, treatment information, and costs of care were abstracted for all eligible patients. We surveyed for prescription opioid utilization subsequent to hospital discharge and through 2018. Negative binomial regression was used to identify factors associated with cumulative prescription opioid use. RESULTS:We identified 3,981 service members with combat-related injuries presenting during the study period. The median age was 24 years (interquartile range [IQR], 22-29 years), 98.5% were male, and the median follow-up was 3.3 years. During the study period, 98% (n = 3,910) of patients were prescribed opioids at least once and were prescribed opioids for a median of 29 days (IQR, 9-85 days) per patient-year of follow-up. While nearly all patients (96%; n = 3,157) discontinued use within 6 months, 91% (n = 2,882) were prescribed opioids again after initially discontinuing opioids. Following regression analysis, patients with preinjury opioid exposure, more severe injuries, blast injuries, and enlisted rank had higher cumulative opioid use. Patients who discontinued opioids within 6 months had an unadjusted median total health care cost of US $97,800
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.