With the advent of newer devices for measuring intracranial pressure (ICP) and cerebral metabolism, more alternatives continue to rise aiming to control ICP. This manuscript presents a proposed analysis of different ICP monitoring devices in order to make appropriate selection of them in our clinical setting including general and pediatric applications. A systematic review of the literature was made analyzing the technical advances in ICP monitoring. The recent in vitro and in vivo tests as well as mathematical/computer models were reviewed. Practical applications of principles were discussed and compared based on the mode of pressure transformation. A ventricular catheter connected to an external strain gauge transducer or catheter tip pressure transducer device is considered to be the most accurate method of monitoring ICP and enables therapeutic CSF drainage. The significant infections or hemorrhage associated with ICP devices causing patients morbidity are clinically rare and should not deter the decision to monitor ICP. Parenchymal catheter tip pressure transducer devices are advantageous when ventricular ICP cannot be obtained or if there is an obstruction in the fluid couple, though they have the potential for significant measurement differences and drift due to the inability to recalibrate. Subarachnoid or subdural fluid-coupled devices and epidural ICP devices are currently less accurate. With an increasing miniaturization of the transducers, fiberoptic systems have been developed, however, there is a problem of measurement accuracy during the period of patient monitoring and external calibration should be performed frequently to ensure constant accuracy. Ventriculostomies continue to have a pivotal role in ICP control. With a rational understanding of the applications and limitations of the different ICP monitoring devices, the outcome for critically ill neurological patients is optimized.
No abstract
The conductance method is sensitive to changes in both concentration and temperature of the intravesical solution, likely due to changes in solution conductivity. Clinical application of conductance for measurement of bladder volume will require real-time conductivity compensation for the dynamically varying properties of urine. However, improved sensitivity at high volumes is necessary before this method has the potential to provide real-time bladder volume measurement for use in ambulatory urodynamics.
A properly functioning aneurysm clip is of paramount importance in the surgical ablation of intracranial aneurysms. An appropriate match between the closing force needed to ablate an aneurysm and the force exerted by the aneurysm clip must be achieved. In this study, the opening and closing forces exerted by several commonly used aneurysm clips were tested. There was a strong correlation between the classification of the clips, according to the Dujovny system, and their mechanical behavior. Minimal variability among different lots of the same clip type and minimal hysteresis were generally exhibited by the alpha mobile fulcrum class clips, such as the Yasargil, Vari-Angle McFadden, Scoville, and Mayfield clips. Significant exceptions included several types of Mayfield and Drake clips. In contrast, pivot class clips generally showed twice as much lot variability among different lots, as well as a significant amount of hysteresis. Clips of this class include the Vari-Angle, Heifetz, and Pivot clips. Because significant variations in clip force exist and because several other factors can compound these differences, it is suggested that aneurysm clips be individually tested for their closing forces before they are used in an operation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.