Under unbalanced grid condition, in a doubly-fed induction generator (DFIG), voltage, current, and flux of the stator become asymmetric. Therefore, active-reactive power and torque will be oscillating. In DFIG controlling rotor side converter (RSC) aims to eliminate power and torque oscillations. However, simultaneous elimination of the power and torque oscillations is not possible. Also, grid side converter (GSC) aims to regulate DC-Link voltage. In this paper, in order to regulate DC-Link voltage, an extended state observer (ESO) based on a generalized proportional-integral (GPI) controller, is employed. In this controlling method, DC-Link voltage is controlled without measuring the GSC current, and due to using the GPI controller, the improved dynamic response is resistant against voltage changes, and the settling time is reduced. A versatile rotor position computation algorithm (RPCA) is utilized to measure the rotor speed. This algorithm is simple, yet it is accurate and is resistant to changes in the resistance of the rotor and stator. The simulations are implemented by MATLAB software in the synchronous positive and negative sequence reference (dq).
Under unbalanced grid condition, in a Doubly-Fed Induction Generator (DFIG), voltage, current, and flux of the stator become asymmetric. Therefore, active-reactive power and torque will be oscillating. In DFIG controlling Rotor Side Converter (RSC) aims to eliminate power and torque oscillations. However, simultaneous elimination of the power and torque oscillations is not possible. Also, Grid Side Converter (GSC) aims to regulate DC-Link voltage. In this paper, in order to regulate DC-Link voltage, an Extended State Observer (ESO) based on a Generalized Proportional-Integral (GPI) controller, is employed. In this controlling method, DC-Link voltage is controlled without measuring the GSC current, and due to using the GPI controller, the improved dynamic response is resistant against voltage changes, and the settling time is reduced. To improve the transient stability and Low Voltage Fault Ride Through (LVRT) capability of DFIG, Statistic Fault Current Limiter (S-FCL) and Magnetic Energy Storage Fault Current Limiter (MES-FCL) are proposed in this paper. The proposed FCL does not only limit the fault current but also fasten voltage recovery. The simulations are implemented by MATLAB software in the synchronous positive and negative sequence reference (d-q).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.