Introduction: Central Venous Pressure (CVP) measurement is the recommended method for assessment of intravascular status in paediatric shock. The role of Ultrasonography guided measurement of respiratory collapsibility in inferior vena cava diameter (IVC-CI) as a newer, non-invasive adjunct to CVP measurement has been evaluated. This study was done to determine the effectiveness of CVP and IVC-CI in predicting fluid responsiveness in cases of paediatric shock. Material and Methods:This prospective observational study was done in 107 fluid refractory shock patients aged 1-14 years. An informed consent was obtained. Baseline vitals, CVP and IVC-CI were measured before and after a crystalloid Fluid Bolus of 20ml per Kg BW. The changes in CVP and IVC-CI were noted and were correlated to the clinical response. A rise of ≥15% in Cardiac Output was taken as positive fluid response.Results: Mean age of the patients was 7.6years (±4.153). The mean CVP in fluid responders and non-responders was 6.58 (±2.64) and 11.22 (±6.12), while the mean IVC-CI was 46.57% (±23.34) and 25.62% (±23.28) respectively. There was significant inverse correlation between CVP and IVC-CI (P<0.01) in both fluid responders and non-responders. At CVP ≤8.25, sensitivity was 80% and specificity was 99% for predicting fluid responsiveness. When IVC-CI was ≥ 33.5%, sensitivity was 87% and specificity was 86%. Thus IVC-CI has better sensitivity put poor specificity to predict fluid responsiveness than CVP. Conclusion:Both CVP and IVC-CI are good predictors of volume responsiveness. A shift from hypovolemic to euvolemic status was associated with gradual fall in mean IVC-CI values with progressive rise of CVP values. IVC-CI can provide a useful guide for non-invasive intravascular volume status assessment in critically ill patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.