Purpose With the COVID-19 crisis, recommendations for personal protective equipment (PPE) are necessary for protection in orthopaedics and traumatology. The primary purpose of this study is to review and present current evidence and recommendations for personal protective equipment and safety recommendations for orthopaedic surgeons and trauma surgeons. UK) for consideration in the presented practice recommendations. Results World Health Organization guidance for respiratory aerosol-generating procedures (AGPs) such as intubation in a COVID19 environment was clear and included the use of an FFP3 (filtering face piece level 3) mask and face protection. However, the recommendation for surgical AGPs, such as the use of high-speed power tools in the operating theatre, was not clear until the UK Public Health England (PHE) guidance of 27 March 2020. This guidance included FFP3 masks and face protection, which UK surgeons quickly adopted. The recommended PPE for orthopaedic surgeons, working in a COVID19 environment, should consist of level 4 surgical gowns, face shields or goggles, double gloves, FFP2-3 or N95-99 respirator masks. An alternative to the mask, face shield and goggles is a powered air-purifying respirator, particularly if the surgeons fail the mask fit test or are required to undertake a long procedure. However, there is a high cost and limited availabilty of these devices at present. Currently available surgical helmets and toga systems may not be the solution due to a permeable top for air intake. During the current COVID-19 crisis, it appeared that telemedicine can be considered as an electronic personal protective equipment by reducing the number of physical contacts and risk contamination. Conclusion Orthopaedic and trauma surgery using power tools, pulsatile lavage and electrocautery are surgical aerosolgenerating procedures and all body fluids contain virus particles. Raising awareness of these issues will help avoid occupational transmission of COVID-19 to the surgical team by aerosolization of blood or other body fluids and hence adequate PPE should be available and used during orthopaedic surgery. In addition, efforts have to be made to improve the current evidence in this regard. Level of evidence IV.
Blood metal ions have been widely used to investigate metal-on-metal hip replacements, but their ability to discriminate between well-functioning and failed hips is not known. The Medicines and Healthcare products Regulatory Agency (MHRA) has suggested a cut-off level of 7 parts per billion (ppb). We performed a pair-matched, case-control study to investigate the sensitivity and specificity of blood metal ion levels for diagnosing failure in 176 patients with a unilateral metal-on-metal hip replacement. We recruited 88 cases with a pre-revision, unexplained failed hip and an equal number of matching controls with a well-functioning hip. We investigated the 7 ppb cut-off level for the maximum of cobalt or chromium and determined optimal mathematical cut-off levels from receiver-operating characteristic curves. The 7 ppb cut-off level for the maximum of cobalt or chromium had a specificity of 89% and sensitivity 52% for detecting a pre-operative unexplained failed metal on metal hip replacement. The optimal cut-off level for the maximum of cobalt or chromium was 4.97 ppb and had sensitivity 63% and specificity 86%. Blood metal ions had good discriminant ability to separate failed from well-functioning hip replacements. The MHRA cut-off level of 7 ppb provides a specific test but has poor sensitivity.
Background Pseudotumors are sterile inflammatory lesions found in the soft tissues surrounding metal-on-metal (MOM) and metal-on-polyethylene hip arthroplasties. In patients with MOM hip arthroplasties, pseudotumors are thought to represent an adverse reaction to metal wear debris. However, the pathogenesis of these lesions remains unclear. Currently, there is inconsistent evidence regarding the influence of adverse cup position and increased wear in the formation of pseudotumors. Questions/purposes We therefore determined whether pseudotumor formation was associated with (1) adverse cup position, (2) raised metal ion levels, and (3) increased wear rates of the retrieved components. Methods We retrospectively reviewed all 352 patients for whom we had retrieved specimens from revisions of a current-generation MOM hip prosthesis between February 2008 and September 2010; of these, 105 met our inclusion criteria. We used multivariate logistic regression analysis to compare acetabular orientation, metal ion levels before revision, and component wear rates between patients with (n = 72) and without (n = 33) pseudotumors, according to findings on metal artifact reduction sequence MRI. Results The proportion of patients demonstrating evidence of a pseudotumor in well-positioned hips was similar to those with adverse cup positions (67% and 66%, respectively). Patients revised with pseudotumors had similar whole-blood metal ion levels and component wear rates to those who were not revised. Conclusions Pseudotumors were not associated with increased wear or metal ion levels, suggesting patient susceptibility is likely to be more important.
It has been speculated that material loss, either as corrosion or wear, at the head-stem taper junction is implicated in the high revision rates reported for metal-on-metal total hip replacements. We measured the volume of material loss from the taper and bearing surfaces of retrieved devices, and investigated the associations with blood metal ion levels and the diagnosis of a cystic or solid pseudotumor. The median volumes of material lost from the female and male taper surfaces were 2.0 and 0.29 mm 3 , respectively, while the median volumes of wear from the cup and head bearing surfaces were 1.94 and 3.44 mm 3 , respectively. Material loss from the female taper was similar to that from the acetabular bearing surface (p ¼ 0.55), but significantly less than that from the femoral bearing surface (p < 0.001). Material loss from the male taper was less than that from both bearing surfaces (p < 0.001). Multivariable analysis demonstrated no significant correlations between the volume of material lost from the taper surfaces and either blood cobalt or chromium ions, or the presence of pseudotumor. While a substantial volume of material is lost at the taper junction, the clinical significance of this debris remains unclear. ß
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.